Series 610 UPS
Battery Cabinet Precautions
Table of Contents
Maintenance
Specifications
Figures
Tables
Important Safety Instructions
System Description
Designed for Success
Reliability
Other Factors to Consider
Safety Precautions
Modes of Operation
Operator Controls
Options
Customer Alarm Interface
Temperature-Compensated Charging
Battery Load Testing
Automatic Restart
General Component Descriptions
Battery Plant
UPS Module
Controls Hardware
Detailed Component Descriptions
Software
Input Power Factor
Rectifier/Charger
Operation
Input Circuit Breaker
Battery Charging Circuit
Battery Disconnect
Battery Charge Current Limiting
Battery Equalize Charge Circuit
Non-Linear Load Characteristics
Unbalanced Load Characteristics
Inverter
Output Regulation and Overload Performance
Static Switch Backfeed Protection
Static Bypass
Bypass Circuit Breaker
Pulsed Parallel Operation
Transfer and Retransfer Conditions
Three Breaker Maintenance Bypass Switchboard
Features
Display Screen and Operator Controls
Operator controls, typical system
100kVA 500kVA 1000kVA Description Function
Series 610 UPS operator control panel
Description Function
Menu Tree Navigation
Menu tree
Master Menu Screen
Master menu screen
Operation
Input Metering Displays
Monitor/Mimic Display Screen
Output Metering Displays
Item 7 Alarm Messages
Status/Alarm Message Areas
Item 6 Status Messages
Monitor/Mimic display example Utility fail
Walk-In Display Screen
Walk-in display screen
Status Reports Screens
Status reports screen
Present Status
Event History
History Status
History status report screen
Battery Cycle Monitor
System Status
Battery cycle monitoring summary screen
System Configuration Screens
System configuration screens
Maximum Auto-Retransfer Attempts
Maximum auto-retransfer attempts screen
Date
Date screen
Time
Time screen
Auto Dial
Auto dial screen
Language Selection
System Options
Continuous Duty Static Switch Optional
Alarm messages
Additional alarm messages
Remote Monitor
Standard Remote Monitor Indications Channel
Alarm Limit Settings Screen
Overload Alarm
Battery Discharging
Low Battery
Battery Shutdown 60 Minutes
Battery Rating 100%
Battery Rating
Temperature Limit Setting Optional
Load Transfer Procedures Screen
Load transfer procedure screen
Start-Up Procedures Screen
Refer to 3.4.1 Start-Up Procedure for more details
Shutdown Procedures Screen
Battery Time Screen
Battery time screen 15-minute discharge
Upper Limit Actual Lower Limit
Elapsed Time Minutes
Meter Calibration Screen
Status Reports Screens
Battery Equalize Screen
Battery equalize screen
Alarm and Status Messages Status Messages
Alarm and status message screen
Alarm Messages
Abbreviations used in alarm messages
Alarm messages and corrective actions
AC Input
UPS System
UPS System
Cooling
Alarm messages-summary
Alarm Message Special Functions
Worldwide Reporting
Communication Interfaces
Auto-Dial
Local Reporting to a Terminal
Local Reporting to a Monitor
Site Reporting SiteScan or Snmp
Requesting Information
Series 610 terminal commands
Remote Monitor Panel
Separate / Simultaneous Outputs
Keys Function
Circuit breaker abbreviations
Load on Bypass
Abbreviation Circuit Breaker
OK to Transfer
Load on bypass UPS available
Load on UPS bypass available
Momentary overload through pulse-parallel static switch
Momentary Overloads
Input Power Failure-Load on Battery
Input power fail-load on battery
Off Battery
Load on UPS-battery not available
Refer to 3.4.4 Shutdown Procedures
Emergency Module Off
Remote Emergency Power Off
Emergency power off
Refer to 3.3.9 Maintenance Bypass
Module Shutdown
Load on maintenance bypass two breakers
Load on maintenance bypass three breakers
Manual Procedures
Start-Up Procedure
Start-Up Procedure
Set the Static Switch Disconnect or to OFF open
Start-up procedures
Start-Up Procedure
Load Transfer Procedures
Load transfer procedures screen
Maintenance Bypass Load Transfers
Shutdown Procedures Module Shutdown Procedure
Shutdown Procedures
Remote Emergency Power Off Repo
Local Emergency Modules Off Lemo
Battery Exercise Procedures
Battery exercise control screen above and results below
Automatic Operations
Overloads Without Transfer
1000%
150%
Automatic Transfers to Bypass Overload Condition
Automatic Retransfers to UPS
Automatic Transfers to Bypass UPS System Faults
Enabling Automatic Restart
Automatic Restart Optional
Sequence of Operation
Maintenance
Liebert Global Services
Maintenance Agreements The Signature Program
Professional Start-Up
Training
Record Log
Routine Maintenance
Air Filters
Limited Life Components
Battery Maintenance
Battery Safety Precautions
Avertissement
Matching Battery Cabinets Optional
Number of Cells Battery Voltage VDC Nominal Float
Battery voltage record
Battery retorque values
Rack-Mounted Batteries
Detection of Trouble
Torque specifications unless otherwise labeled
Torque Requirements
Reporting a Problem
Upstream Feeder Circuit Breaker Setting Inspections
Corrective Actions
Recommended Test Equipment
Rating
Power factor pf KVA
KVA
Specifications applicable to environment
Environmental Conditions
Adjustments
Battery Operation
Electrical Specifications
Page
Technical Support/Service
Company Behind the Products
Locations
United States