Lightwave Communications LDX-3232 manual Mode

Models: LDX-3232

1 118
Download 118 pages 53.85 Kb
Page 50
Image 50

C H A P T E R 3

REMOTE OPERATI ON

Error Messages

Error Code

Explanation

E-501

LASER interlock disabled output

 

 

E-503

LASER open circuit disabled output

 

 

E-504

LASER current limit disabled output

 

 

E-505

LASER voltage limit disabled output

 

 

E-507

LASER power limit disabled output

 

 

E-510

LASER out of tolerance disabled output

 

 

E-511

LASER control error disabled output

 

 

E-512

Analog section status is all 1’s or all 0’s (power down)

 

 

E-513

Serial EEPROM checksum error

 

 

E-515

Laser output must be off to change ranges

 

 

E-516

Incorrect configuration for calibration sequence to start

 

 

E-519

Setting a measurement is only valid during the calibration phase for that measurement;

 

user has tried to calibrate a measurement without first entering the required calibration

 

mode.

34 LDX-3232

Page 50
Image 50
Lightwave Communications LDX-3232 manual Mode