C H A P T E R 4

COMMAND REFERENCE

LDX-3232 Device-Dependent Command Reference

TIMER?

 

 

 

 

FRONT PANEL

 

 

 

 

REMOTE

 

 

 

 

 

 

The TIMER? query allows the programmer to determine how much time has passed

 

since the last TIMER? query was issued.

 

 

:

TIMER

?

 

 

 

 

 

- where the response is character data that represents hours:minutes:seconds.

Notes

Each time the TIMER? query is issued, the timer is reset to 0 and the elapsed time since

 

the last TIMER? query is returned.

 

The timer counter is initially set at power-up, the same as the TIME? counter. So the first

 

time the TIMER? is issued its response will be the same as if a TIME? query's response.

Examples

"Timer?" -response: 00:02:00.31, means the LDX-3232 has been on for two minutes and

 

0.31 seconds since the last TIMER? query was issued.

"TIMER?" -response: 00:00:12.03, means the LDX-3232 has been on for 12.03 seconds since the last TIMER? query was issued.

82 LDX-3232