7193 Owner’s Guide

Communication

Parallel Switch Settings

The DIP switches are not used by the Parallel interface except for selecting the size of the data buffer and for running diagnostic tests, which must be done while the printer is in level 1 diagnostics (setup mode) with switch 1 set to On. See “Level 1 Diagnostics” in the “Diagnostics” chapter for more information.

When switch 1 is set to Off, the printer is on-line and ready to communicate with the host system. Switches 2-6 are not used at any time the printer is on-line, and they are set to Off at the factory.

Caution: The switches can also be used for setting other functions and tests. Be careful when setting the switches for the Data Buffer settings that you do not accidentally change the settings for the other functions and tests.

Note: The Data Buffer option is set with the printer in the setup mode. See “Level 1 Diagnostics” in the “Diagnostics” chapter for more information.

Switch 1

Switch 2

Switch 3

Switch 4

Switch 5

Switch 6

Option

Off

Off

Off

Off

Off

Off

On-line

On1

Off

On

Off

On

Off

4K Byte Data Buffer2

On1

Off

On

Off

On

On

One Line Data Buffer

1Printer is off-line

2Default

Choose one of the Data Buffer options.