Module 8102-03-X

Module 8102-03-X provides a two port internal bridge for bridging 10Mbps and 100Mbps segments or 100BASE-FX distance extender with SC type connectors for fiber cable. The internal bridge must be enabled with on board jumpers before installation. The external distance extender is enabled by default. Module flow-control (backpressure) can be enabled or disabled by setting the on board jumpers before installation.

The default settings are as follows:

Bridge Function setting: Internal disabled (Default)

Backpressure setting: Disabled (Default)

Module 8102-03-X Bridge Jumpers

The default jumper setting of the Module 8102-03-X is internal bridge disabled. To enable the internal bridge and disable the external bridge change the jumpers (JP2~JP17) from 2&3 to 1&2.

Jumpers JP2~JP17

1&2 connected = internal bridge is enabled

2&3 connected = external bridge is enabled (Default)

8102-03-X Duplex Jumper

When the Module 8102-03-X internal bridge is enabled, the duplex jumper should be set to Half Duplex.

Jumper JP1

1&2 = half-dulex enabled

2&3 = full-duplex enabled

Module 8102-03-X Backpressure Jumpers

The default jumper setting for backpressure is disabled. To enable the backpressure function, change JP19 jumper to 2&3.

Jumper JP19

1&2 = disabled (Default)

2&3 = enabled

2

3 Ports

Switch Module

LINK

TX FDX

RX COL

32 CenturyStack 8100 Managed Hub

Page 32
Image 32
METRObility Optical Systems 8124-01-M manual Module 8102-03-X Bridge Jumpers, Duplex Jumper