Module 8102-01-X

Module 8102-01-X is either an internal bridge for bridging the internal 10Mbps and 100Mbps segments or an external 10/100BASE-TX distance extender with MDI-X and MDI-II interfaces using an RJ-45 cable. Only one of these functions can be enabled at one time. The internal or external bridge must be enabled or disabled with on board jumpers before installa- tion. Module flow-control (backpressure) can be enabled or disabled by setting the on board jumpers before installation. The default settings are as follows:

Bridge Function setting: Internal (Default)

Backpressure setting: Disabled (Default)

Module 8102-01-X Bridge Jumpers

The default jumper setting of the 8102-01-X module is internal bridge enabled. To disable the internal bridge and enable the external bridge, change the jumpers (JP1~JP16) from 1&2 to 2&3.

Jumpers JP1~JP16

1&2 connected = internal bridge is enabled (Default)

2&3 connected = external bridge is enabled

Module 8102-01-X Backpressure Jumpers

The default jumper setting for backpressure is disabled. To enable the backpressure function, change JP18 jumper to 2&3.

Jumper JP18

1&2 =disabled (Default)

2&3 = enabled