GroupReset

All, some or none of the group’s function can be changed by selecting one of these options:

NOTE: The selected option takes effect after SAVE is executed.

No Reset: None of these are reset.

Reset All: The function logic and counters of the group will

 

be reset. This is identical to cold restart.

Reset Function Logic Only:

The function logic of the group

will be reset. The counters will be held static and will not be reset. This reset operation will reset the link status of each port to ‘Link Down’. That will cause a Link Status Change event to be raised.

Reset Counters Only: The counters of each port will be reset to 0, but the function logic will be held static and will not be reset.

Group Name: The name assigned to this hub.

GroupLastChangeNotify

Enable: Sends out a trap when the value of this field changes.

Disable: Does not send out a trap when the value of this field changes.

Tochangethesettingofagivengroup:

1.Select the group by number.

2.Set the new value to the Group Admin State.

3.Set reset request to the Group Reset field.

4.Type in the name of the Group Name field.

5.Set Group Last Change Notify field.

6.Select <Save>.