Chapter 4
Master Hub Configuration
and Console Management
This Chapter is only for CenturyStack Master Hub configuration and management. When installing CenturyStack the first time, it is necessary to configure the hub through the Console Interface.
Connecting to the Console Interface
You can set up a management session by connecting a direct
To connect a local terminal to the CenturyStack, do the following:
1.Install a terminal emulation application such as Windows Hyperterminal on your PC.
2.Configure the terminal emulation application as follows:
Baud rate ....... 9600 Parity .............. None Data bits ......... 8 Stop bits ......... 1 Flow Control ... None
3.If you are using Microsoft Windows terminal emulation, disable the “Use Function, Arrow, and Ctrl Keys for Windows” option in the Terminal Preferences menu under Settings.
4.Connect the console management port on the CenturyStack to your PC or DTE device using a serial cable. The CenturyStack has a
Network Management Unit
(NMU) Module
Stackable
Up
Down
NMU
AC LINE
Switch/
Transceiver
Connecting the Console Interface