•Suspend: Indicates that the active ports are disabled and the redundant link function is temporarily suspended until you set its state to enable.
NOTE: The suspend state does not cause the port to be switched over.
•Invalid: Purge the configuration of a redundant link pair from the system database.
•
Configuring Link Pairs
1.Select a Link Pair.
2.Enter the Primary Link Group (1 to 6).
3.Enter the Primary Link Port (1 to 12/24).
4.Enter the Secondary Link Group (1 to 6).
NOTE: You can configure and save the Secondary Link Group and the Primary Link Group as the same hub, however, this will be of no use in the event of a hub failure.
5.Enter the Secondary Link Port (1 to 12/24).
6.Enable the Link Switch Over Notify. (Optional)
7.Enable the Status.
8.Select <Save> to update the new Linked Pair. Repeat these steps for each Link Pair.