4G9 ENGINE (E–W)Water Pump and Water Hose

11A-7-5

INSTALLATION SERVICE POINTS

"AAWATER PUMP INSTALLATION

(1)Apply 3 mm diameter of Form-In-Place Gasket (FIPG) to the location shown in the illustration.

Specified sealant:

Mitsubishi Genuine Part No.MD970389 or equivalent

"BAWATER INLET PIPE <FRONT WHEEL DRIVE>/WATER PIPE <REAR WHEEL DRIVE>/O-RING INSTALLATION

(1)Replace the O-ring of the water inlet pipe <FRONT WHEEL DRIVE> or water pipe <REAR WHEEL DRIVE>, and then apply water to the O-ring to make installation easy.

Caution

1.Never apply any oil or grease to the O-ring.

2.Secure the water pipe after the thermostat case has been installed.

"CATHERMOSTAT CASE INSTALLATION

(1)Apply 3 mm diameter of Form-In-Place Gasket (FIPG) to the location shown in the illustration.

Specified sealant:

Mitsubishi Genuine Part No.MD970389 or equivalent

"DATHERMOSTAT INSTALLATION

(1)Install the thermostat so that the jiggle valve is facing straight up.

Jiggle valve

<FRONT WHEEL DRIVE>

"EA WATER OUTLET FITTING INSTALLAT

(1)Apply 3 mm diameter of Form-In-Place Gasket (FIPG) to the location shown in the illustration.

Specified sealant:

Mitsubishi Genuine Part No.MD970389 or equivalent

EMitsubishi Motors CorporationJun.2002

PWEE9502-K

Revised