Event Log Messages

B-23

Unit Update

Code

Event Log Messages

Level

Cable Modem Actions

 

 

 

 

X500.0

Attempting Unit Update.

7(Info)

No action needed.

 

 

 

 

X501.0

Can’t allocate memory to read UU data

2(Alert)

Continue using current image. CM is

 

from flash

 

out of memory. Try rebooting CM. If

 

 

 

problem persists contact your vendor.

 

 

 

 

X501.1

Can’t read Unit Update data from flash.

4(Error)

Update will complete. If problem

 

 

 

persists contact your vendor

 

 

 

 

X501.2

Can’t write Unit Update data to flash.

4(Error)

Update will complete, but value for

 

 

 

docsDevSwOperStatus may be

 

 

 

incorrect after CM reboots. If problem

 

 

 

persists contact your vendor.

 

 

 

 

X501.4

Provisioned Unit Update skipped. Image

7(Info)

CM did not perform a provisioned Unit

 

is current.

 

Update because it is already running

 

 

 

the image it was told to download. No

 

 

 

Action needed.

 

 

 

 

X501.5

Unable to create UnitUpdate Task.

2(Alert)

Update failed. CM was unable to

 

 

 

create the task to do the update.

 

 

 

Reboot CM and try the update again.

 

 

 

If problem persists contact your

 

 

 

vendor.

 

 

 

 

X501.6

Unit Update Failed. Reached Max

4(Error)

Unit Update failed. The TFTP transfer

 

Retries.

 

failed 16 times in a row.

 

 

 

 

X501.7

Unable to write image file to flash

4 (Error)

Continue using current image file.

 

 

 

Possibly troubleshoot flash.

 

 

 

 

X501.8

Unit Update From SNMP...... SUCCESS

7(Info)

No action taken

 

 

 

 

X501.9

Unit Update From CLI...... SUCCESS

7(Info)

No action taken

 

 

 

 

X501.10

Unit Update From Config File

7(Info)

No action taken

 

SUCCESS

 

 

 

 

 

 

X501.11

Unit Update Image length is invalid.

4 (Error)

Continue using current image. Unit

 

Length = [length]

 

update failed. Image is too large,

 

 

 

probably bad image file. Obtain new

 

 

 

image file.

 

 

 

 

X501.12

Unit Update MD5 Checksum Failed.

4(Error)

Continue using current image. Update

 

Image corrupt.

 

failed. Image is corrupted. Get new

 

 

 

copy of image file.

 

 

 

 

X501.13

Unit Update: Could not write App image

2(Alert)

Continue using current image. Update

 

to flash.

 

failed. System could not write the new

 

 

 

image to the flash. Try operation

 

 

 

again. If problem persists, contact your

 

 

 

vendor.

 

 

 

 

X501.14

Unit Update: Could not write Header to

2(Alert)

Continue using current image. Update

 

flash.

 

failed. System could not write the new

 

 

 

image header to the flash. Try

 

 

 

operation again. If problem persists,

 

 

 

contact your vendor.

 

 

 

 

SURFboard Cable Modem Installation Manual

Page 95
Image 95
Motorola DHSB5100 X500.0, X501.0, X501.2, X501.4, X501.5, X501.6, X501.7, X501.8, X501.9, X501.10, X501.11, X501.12