Multi-Tech Systems DT102/xx 9. Composite Link Statistics, Troubleshooting, Step Procedure

Models: DT102 DT101 DT102/xx DT101/xx

1 154
Download 154 pages 12.82 Kb
Page 103
Image 103
7.9 Composite Link Statistics

Chapter 7 - Troubleshooting

7.9 Composite Link Statistics

Table 7-9. Composite Link Statistics

Step Procedure

1Toggle DIP switch position 3 to the down (closed) position to enable the command port.

2Connect a terminal or PC running communications software to the DATA/COMMAND connector on the back panel of the DataTalker.

Note: Any cables connected to the computer should be shielded to reduce interference.

3Apply power to the DataTalker.

4Apply power to the terminal or PC. Run the PC’s communications software in terminal mode and press ENTER twice to establish communications with the DataTalker. The Main Menu appears:

Main Menu

1 - Configurations

2 - Statistics

3 - Reset Options

4 - Diagnostics

5 - Exit Command Mode

6 - QUICK SETUP

Selection : _

5 Enter 2 and press ENTER. The Statistics menu is displayed:

Statistics

1- View Composite Link Statistics

2- Clear Composite Link Statistics M - Main Menu

P - Previous Menu

Selection : _

6 Enter 1 and press ENTER to view the composite link statistics:

Composite Link Statistics

 

 

Elasped Time

: 00 Days 00 Hours 00

Minutes

 

 

Data Blocks Transmitted

:

0

Data Blocks Retransmitted

:

0

Data Blocks Received

:

0

Receive Block Errors

:

0

Voice/Fax Blocks Transmitted

:

0

Voice/Fax Blocks Received

:

0

Link Alarms

:

0

Remote Downs

:

0

103