Multi-Tech Systems DT102, DT101/xx Configuration 4 - PBX to PBX, Remote Site, Local Site

Models: DT102 DT101 DT102/xx DT101/xx

1 154
Download 154 pages 12.82 Kb
Page 32
Image 32
2.5 Configuration 4 - PBX to PBX

DataTalker Owner’s Manual

2.5 Configuration 4 - PBX to PBX

Configuration 4 is a data/voice/fax configuration that uses two DataTalkers to link two PBXs. Using a single ISDN composite link, they connect a minicomputer and a PBX E&M trunk at the local site to a remote PC on the data part of the network and a second PBX E&M trunk on the voice/fax channel. The configuration is shown in Figure 2-4.

Asynchronous Channel

Asynchronous Channel

DataTalker

PC

ISDN

Composite Link

DataTalker

Voice/Fax

Channel 1 E&M

PSTN

Trunk

PSTN

Trunk

 

Trunk

Station

Station

 

Minicomputer

 

Voice/Fax

Trunk

Channel 1 E&M

Trunk

 

Trunk

 

Station

 

Station

 

PBX

Telephone

PBX

Telephone

 

Remote Site

Figure 2-4. PBX to PBX Configuration

Local Site

At both the local and the remote sites, connect the DATA/COMMAND connector on the DataTalker to an asynchronous port on the computer; connect the DSU/TA DIGITAL jack on the DataTalker to the jack for the ISDN service; and connect the VOICE/FAX CHANNEL 1 E&M jack on the DataTalker to a PBX E&M trunk connector. When you are making an E&M connection, you should also run a ground wire from the ground connector on back of the DataTalker or the RackTalker rack to a ground connection on the PBX.

Before you install the DataTalkers, you must configure them. To configure a DataTalker, place DIP switch position 3 in the down (closed) position and connect a command port device such as a terminal or a PC to the DATA/COMMAND connector on the back of the DataTalker. Turn on the DataTalker and PC and run your communications software in terminal mode. (Set it for direct connection at a serial port speed of 19,200 bps or slower.) Press the ENTER key to establish communications with DataTalker. The Main Menu will appear.

The Main Menu provides access to a series of configuration menus providing simple and complete configuration information for each aspect of the DataTalker. From the Main Menu, you can configure the unit, display statistics, reset various functions within the MMV, and run diagnostic tests:

Main Menu

1 - Configurations

2 - Statistics

3 - Reset Options

4 - Diagnostics

5 - Exit Command Mode

6 - QUICK SETUP

Selection : _

To configure the DataTalker, enter 1 and press ENTER.

32