7.12Diagnostic Testing

Chapter 7 - Troubleshooting

7.12Diagnostic Testing

Table 7-12. Diagnostic Testing

Step Procedure

1Toggle DIP switch position 3 to the down (closed) position to enable the command port.

2Connect a terminal or PC running communications software to the DATA/COMMAND connector on the back panel of the DataTalker.

Note: Any cables connected to the computer should be shielded to reduce interference.

3Apply power to the DataTalker.

4Apply power to the terminal or PC. Run the PC’s communications software in terminal mode and press ENTER twice to establish communications with the DataTalker. The Main Menu appears:

Main Menu

1 - Configurations

2 - Statistics

3 - Reset Options

4 - Diagnostics

5 - Exit Command Mode

6 - QUICK SETUP

Selection : _

5 Enter 4 and press ENTER. The Diagnostics menu is displayed:

Diagnostics

1 - Loop Test

2 - Memory Test

3 - Watch Dog Test

4 - Dip Switch Definitions and Settings

5 - Product and Firmware ID

M - Main Menu

P - Previous Menu

Selection : _

6Select the test you wish to run by entering its option number and pressing ENTER. If you select Loop Test, the Loop Test menu will appear.