Multi-Tech Systems DT102/xx 1. Command Port Troubleshooting, Problem, Possible Causes, Solution

Models: DT102 DT101 DT102/xx DT101/xx

1 154
Download 154 pages 12.82 Kb
Page 91
Image 91
Table 7-1. Command Port Troubleshooting

Chapter 7 - Troubleshooting

Table 7-1. Command Port Troubleshooting

Problem

Possible Causes

Command port device not

Communications software not

communication with DataTalker

installed on command port PC

Command port not enabled

Bad cable or cable connection

Solution

1.Install communications software on command port PC (refer to communcations software documentation of installation instructions).

1.Set DIP-Switch #3 to the closed (down) position.

1.Check RS-232 cable connections between command port device and Command port on DataTalker for loose connections or bent pins.

2.Check RS-232 cable connections between command port device and Command port on DataTalker for correct cable wiring (see cabling diagrams in Appendix C).

3.Call Tech Support for assistance (see Chapter 8).

Table 7-2. Composite Link Troubleshooting Internal DSU

Problem

Possible Causes

Solution

Composite link down with CTS,

DSU not communication with

Verify that the DSU LED is on. If

XMT, and RD LED on

communication line

off, ensure that DIP-Switch #2 is in

 

 

the open (up) position.

 

 

Verify that a cable is connected to

 

 

the internal composite DSU/TA

 

 

Digital connector.

 

 

Verify DSU configuration. See

 

 

Composite Link Settings - Internal

 

 

DSU in Table 7-5.

 

 

Call Tech Support for assistance

 

 

(see Chapter 8).

 

Faulty communication line

Call phone company and verify

 

 

communication line.

 

 

Call Tech Support for assistance

 

 

(see Chapter 8).