Multi-Tech Systems DT102/xx Configuration, Composite Link Settings - Internal DSU, Speed, Menu

Models: DT102 DT101 DT102/xx DT101/xx

1 154
Download 154 pages 12.82 Kb
Page 27
Image 27
Composite Link Settings - Internal DSU

Chapter 2 - Configuration

The data port in this configuration will be set up for synchronous operation. To configure the data port for sync operation, enter 1 (Aysnc/Sync) option and change the default Async to Sync. The data port configuration menu displays the sync parameters.

Data Port Configuration

 

1

- Async/Sync:

Sync

2

- Speed:

19200

3

- Clocking:

Internal

4

- Idle Condition:

Flags

5

- NRZ/NRZI Encoding:

NRZ

6

- CRC Preset:

All 1s

7

- Inter-frame Timer:

Off

S - Store All Configuations

M - Main Menu

P - Previous Menu

Selection : _

Enter 2 and press ENTER to set the speed of the sync data port. Select the appropriate speed by entering its menu list number. The speed you select should be no faster than the composite link speed. At the sync data port configuration menu, determine who is supplying the clocking.

The default internal clocking allows the DataTalker to supply the clock. Enter the letter S to store all configurations and then press P to return to the previous menu.

For configuration 2, where both sites have a telephone connected to the DataTalker, initially accept the defaults for the second choice in the Configurations menu, Voice/Fax Channels Configuration.

At the Configurations menu, enter 3 and press ENTER to display the Composite Link Settings menu.

The DataTalker detects the type of link device being used from the way a DIP switch is set or by reading the device when it is installed on the main PC board. In this configuration, a 56K bps internal DSU is being used as the composite link device. So, when the internal composite link settings menu is displayed, it is for a DSU:

Composite Link Settings - Internal DSU

1

-

Speed:

56k

2

-

Clocking:

DDS

S

-

Store

All

Configurations

M

-

Main

Menu

 

P

-

Previous

Menu

Selection

: _

 

The internal DSU has two options: speed and clocking. The speed option should match the DDS line speed. The clocking option depends on how you have set up your link with the telephone company. If the link is set up as a DDS link, use the default DDS setting. If the link is set up for the DataTalker to provide the clocking, change the clocking option to Internal.

This completes the configuration of both DataTalkers. Disconnect the data/command port from the terminal or PC and connect it to the composite link of the MMH904. Place DIP switch position 3 on both DataTalkers in the up (OPEN) position to change the data/command port over to a data channel.

27

Page 27
Image 27
Multi-Tech Systems DT102/xx, DT101/xx Composite Link Settings - Internal DSU, Speed, Configurations, Menu, Main