DataTalker Owner’s Manual

Table 7-3 Data Channel Troubleshooting

ProblemPossible CausesSolution

Async Data Channel

Channel Device not

Incorrect channel parameter

1.

Verify configuration of data

communicating with DataTalker;

settings

 

port (see Data Port

composite link up with CD,,

 

 

Configuration in Table 7-10).

CTS, XMT, RCV and RD LEDs

 

2.

Call Tech Support for

on

 

 

 

assistance (see Chapter 8).

 

 

 

 

Channel device incorrectly cabled

1.

See cabling diagrams in

 

 

 

Appendix B and C on both

 

 

 

DataTalker and data channel

 

 

 

device.

 

 

2.

Call Tech Support for

 

 

 

assistance (see Chapter 8).

Async Data Channel device

Flow control not properly set

1.

Verify flow control options for

losing data

 

 

the async data channel device

 

 

 

(see Table 7-10).

Sync Data Channel

Channel Device not communicating with DataTalker; composite link up with CD,, CTS, XMT, RCV and RD LEDs on

Incorrect channel parameter settings

Channel device incorrectly cabled

Incorrect Data Type

Incorrect Clocking

1.Verify configuration of data port (see Data Port Configuration in Table 7-10).

2.Call Tech Support for assistance (see Chapter 8).

1.See cabling diagrams in Appendix B and C on both DataTalker and data channel device.

2.Call Tech Support for assistance (see Chapter 8).

1.Verify that sync device uses HDLC or SLDC protocol, NRZ encoding, and operates in full duplex.

1.If sync device expects clock to come from DataTalker on pins 15 and 17, set DataTalker sync data channel to internal clocking and set speed.

2.If sync device provides click to DataTalker on pin 24, confiugre sync data channel for external clocking.