Multi-Tech Systems DT101/xx, DT102/xx owner manual DataTalker Owner’s Manual, Enter

Models: DT102 DT101 DT102/xx DT101/xx

1 154
Download 154 pages 12.82 Kb
Page 30
Image 30
ENTER.

DataTalker Owner’s Manual

Data Port Configuration

 

1

- Async/Sync:

Sync

2

- Speed:

19200

3

- Clocking:

Internal

4

- Idle Condition:

Flags

5

- NRZ/NRZI Encoding:

NRZ

6

- CRC Preset:

All 1s

7

- Inter-frame Timer:

Off

S - Store All Configuations

M - Main Menu

P - Previous Menu

Selection : _

Press P to return to the Data Port Configuration menu, enter S to store all configurations, and then press P again to return to the previous menu. At the Configurations menu, enter 2 and press

ENTER.

The Voice/Fax Channel 1 Configuration menu is displayed. For LAN 1, set voice/fax channel 1 for an FXO connection as the local interface type (option 6), and keep the default FXS as the remote interface type (option 11). LAN 2 must be set just the opposite (FXS for the local interface and FXO for the remote interface). For the other selections, accept the defaults .

Voice/Fax Channel 1 Configuration

1

-

Destination Channel

: 1

2

-

Digitizing Rate

: 9600

3

-

Output

Level Atten.

: 12

4

-

Input Level Gain

: 03

5

-

Silence Suppression

: Off

6

-

Local Interface Type

: FXS

7

-

Ground/Loop Start (FXS)

: Loop

8

-

2 or

4 Wire (E&M)

: N/A

9

-

Dialtone/Wink (E&M)

: N/A

10 -

Wink

Timer (E&M)

: N/A

11 -

Remote

Interface Type

: FXS

12 -

Ground/Loop Start (FXS)

: Loop

13 -

2 or

4 Wire (E&M)

: N/A

14 -

Dialtone/Wink (E&M)

: N/A

S- Store All Configurations M - Main Menu

P - Previous Menu

Selection : _

Enter S and press ENTER to store all configurations for LAN 1.

Set up LAN 2 in the same manner, but switch the local and remote interface types (FXS for the local interface and FXO for the remote interface). When you have finished selecting the LAN 2 options, enter S to store all configuration. Enter P to return to the Configurations menu.

At the Configurations menu, enter 3 and press ENTER to display the composite link configuration menu.

30

Page 30
Image 30