DataTalker Owner’s Manual

Voice/Fax Channel 1 Configuration

1

- Destination Channel

: 1

2

- Digitizing Rate

: 9600

3

- Output Level Atten.

: 12

4

- Input Level Gain

: 03

5

- Silence Suppression

: Off

6

- Local Interface Type

: FXS

7

-

Ground/Loop Start (FXS)

: Loop

8

-

2 or 4 Wire (E&M)

: N/A

9

-

Dialtone/Wink (E&M)

: N/A

10

-

Wink Timer (E&M)

: N/A

11

- Remote Interface Type

: FXS

12

-

Ground/Loop Start (FXS)

: Loop

13

-

2 or 4 Wire (E&M)

: N/A

14

-

Dialtone/Wink (E&M)

: N/A

S- Store All Configurations M - Main Menu

P - Previous Menu

Selection : _

7Verify the voice/fax channel configuration. To change the configuration, enter the appropriate option numbers.

Options 1 through 10 are for the local interface. Options 11 through 14 are for the remote interface. Note that the remote interface options do not actually change the remote interface; they only tell the local DataTalker how the remote interface is configured. Any changes in the remote interface must be done at the remote site. See Chapter 6 for descriptions of the Voice/Fax Channel 1 Configuration menu options.

8When all the options for the voice/fax channel are set, enter S and press ENTER to store all configurations. Then enter M and press ENTER to return to the Main Menu.

9Disconnect the terminal or PC from the command port and place DIP switch position 3 in the up (OPEN) position to change the command/data port over to a data channel.

108

Page 108
Image 108
Multi-Tech Systems DT101/xx, DT102/xx owner manual 108, Fxs