Chapter4 ConnectingSignals
©NationalInstruments Corporation 4-13 ATE Series User Manual
PFI6/WFTRIG DIO Vcc+0.5 3.5 at
(Vcc0.4)
5at0.4 1.5 50kpu
PFI7/STARTSCAN DIO Vcc+0.5 3.5 at
(Vcc0.4)
5at0.4 1.5 50kpu
PFI8/GPCTR0_SOURCE DIO Vcc+0.5 3.5 at
(Vcc0.4)
5at0.4 1.5 50kpu
PFI9/GPCTR0_GATE DIO Vcc+0.5 3.5 at
(Vcc0.4)
5at0.4 1.5 50kpu
GPCTR0_OUT DO 3.5at
(Vcc0.4)
5at0.4 1.5 50kpu
FREQ_OUT DO 3.5at
(Vcc0.4)
5at0.4 1.5 50kpu
AI= Analog Input DIO= Digital Input/Output pu= pull up
AO= Analog Output DO= Digital Output
Thetolerance on the 50 kpull-up and pull-down resistors is very large. Actual value may range between 17 kand 100 k.
Table4-6. I/O Signal Summary for the AT-MIO-16XE-50
SignalName Drive
Impedance
Input/
Output
Protection
(Volts)
On/Off
Source
(mAat V)
Sink
(mAat V)
Rise
Time
(ns) Bias
ACH<0..15> AI 20Gin
parallelwith
100pF
25/15 ±3 nA
AISENSE AI 20Gin
parallelwith
100pF
25/15 ±3 nA
AIGND AO — — —
DAC0OUT AO 0.1 Short-circuit
toground
5at10 5at10 2
V/µs
DAC1OUT AO 0.1 Short-circuit
toground
5at10 5at10 2
V/µs
AOGND AO — — —
DGND DO — — —
Table4-5. I/O Signal Summary for the AT-MIO-16XE-10 and AT-AI-16XE-10(Continued)
SignalName Drive
Impedance
Input/
Output
Protection
(Volts)
On/Off
Source
(mAat V)
Sink
(mAat V)
Rise
Time
(ns) Bias