Chapter4 ConnectingSignals
©NationalInstruments Corporation 4-35 ATE Series User Manual
before TRIG2 can berecognized. A fter the scan counter decrements to
zero,it is loaded with the number of posttrigger scans to acquire while the
acquisitioncontinue s. The deviceignores the TRIG2 signal if it is asserted
priort o the scancounter decrementing to zero. After the selected edge of
TRIG2 is received,the device acquires a fixed number of scans and the
acquisitionstops. This mode acquires data both beforeand after receiving
TRIG2.
As ano utput, the TRIG2 signal reflects the posttrigger in a pretriggered
acquisition sequence, evenif the acquisitio n isb eing externally triggered
byanother PFI. The TRIG2 signal is not used in posttriggered data
acquisition. The output is an activehigh pulse with a pulse width of
50 to 100 ns. This output is set to high-impedance at startup.
Figures 4-17 and 4-18 showthe input and outp ut timing requirements for
the TRIG2 signal.
Figure4-17. TRIG2 Input Signal Timing
Figure4-18. TRIG2 Output Signal Timing
Rising-Edge
Polarity
Falling-Edge
Polarity
tw=10 ns minimum
tw
tw=50to100ns
tw