Chapter4 ConnectingSignals
ATE Series User Manual 4-34 ni.com
Figures 4-15 and 4-16 show the input and output timing requirements for
the TRIG1 signal.
Figure4-15. TRIG1Input Signal Timing
Figure4-16. TRIG1Output Signal Timing
The devicealso uses the TRIG1 signal to initiate pretriggered DAQ
operations. In most pretriggered applications, the TRIG1 signal is
generated bya software trigger. Refer to the TRIG2 signal description for
acomplete description of the use of TRIG1 and TRIG2 in a pretriggered
DAQoperation.
TRIG2 Signal
Any PFIpin can externally input the TRIG2 signal, which is available as
an output on the PFI1/TRIG2 pin.
Refert o Figure 4-13 for the relationship of TRIG2 to the DAQsequence.
As aninput, the TRIG2 signal is configured in the edge-detection mode.
Youcan select any PFI pin as the source for TRIG2 and configure the
polarityselection f or either rising or falling edge. The selected edge of the
TRIG2signal initiates the posttriggered phase of a pretriggered acquisition
sequence. In pretriggered mode, the TRIG1 signal initiates the data
acquisition. The scan counter indicates the minimum number of scans
Rising-Edge
Polarity
Falling-Edge
Polarity
tw=10 ns minimum
tw
tw=50to100ns
tw