5.Push the ejector to lock the stopper. The FC Switch Module is fixed.

„The installation/removal procedures of the FC Switch Module in/from a Blade Enclosure (SIGMABLADE) vary depending on the Blade Enclosure (SIGMABLADE) you use. For the procedure, always refer to the relevant Blade Enclosure (SIGMABLADE).

„If a FC Switch Module cannot be installed in a Blade Enclosure (SIGMABLADE) properly, remove the FC Switch Module once and reinstall it again. Applying excess force to the FC Switch Module may cause it to be damaged. After the FC Switch Module is removed, wait for more than 10 seconds and then reinstall it.

„Insert FC Switch Modules into switch module slots on a Blade Enclosure (SIGMABLADE) corresponding to the locations on which fibre channel controllers are installed. Without the correspondences, peripherals cannot be connected to the FC Switch Modules. Refer to the User’s Guides of the Blade Enclosure (SIGMABLADE), CPU blade and/or the fibre channel controller for details.