USER MANUAL
ENGLISH
Hydraulic system data | Values |
Maximum drive system pressure | 250 Bar |
|
|
Maximum accessory system pressure | 120/200 Bar |
|
|
Hydraulic system oil (at ambient temperature above 10°C) | AGIP Arnica 46 (****) |
|
|
NOTE
If the machine is to be used at ambient temperatures below 10°C, the oil should be replaced with equivalent oil having a viscosity of 32 cSt. For temperatures below 0°C, use oil with lower viscosity.
(****) | See the below hydraulic system oil technical data and reference data tables. |
SPECIFICATIONS
AGIP ARNICA |
| 46 | 32 |
|
|
|
|
Viscosity at 40°C | mm²/s | 45 | 32 |
|
|
|
|
Viscosity at 100°C | mm²/s | 7.97 | 6.40 |
|
|
|
|
Viscosity index | / | 150 | 157 |
|
|
|
|
Flash point COC | °C | 215 | 202 |
|
|
|
|
Pour point | °C | ||
|
|
|
|
Density at 15°C | kg/l | 0.87 | 0.865 |
|
|
|
|
REFERENCE DATA
ISO 11158
AFNOR NF E 48603 HV
AISE 127
ATOS Tab. P
BS 4231 HSE
CETOP RP 91 H HV
COMMERCIAL HYDRAULICS
Danieli Standard 0.000.001 (AGIP ARNICA 22, 46, 68)
EATON VICKERS
EATON VICKERS
DIN 51524 t.3 HVLP
LAMB
LINDE
PARKER HANNIFIN (DENISON)
REXROTH RE
Climate control system data (optional) | Values |
|
|
Gas type | Reclin 134a |
|
|
Gas quantity | 0.8 kg |
|
|
ENVIRONMENTAL CONDITIONS
In the environment where the machine operates, there must not be any danger of explosion.
To avoid inhaling exhaust gas, the machine must be used only where there is a proper air change.
The machine operates correctly (*) in the following environmental conditions:
–Temperature:
–Humidity: 30% to 95%
(*)When using the sweeper at a temperature between
RS 501
33015501(3)2008-02 A
11