Connecting the power supply cables to the BIP

To connect the power supply cables to the BIP:

1Locate one of the power supply cables.

2Match the labeled tag on the power supply cable with the correct location on the power terminal block (Figure 32).

The power terminal block label indicates a location for the positive and negative power supply leads for both the upper shelf and lower shelf power supplies.

3Loosen the appropriate power terminal block screw, and then insert the cable lead (item 1 in Figure 32). Tighten the screw securely.

Item 2 in Figure 32 shows the negative cable lead from power supply 1 in the upper shelf correctly connected to the power terminal block.

Figure 32 Attaching power supply cable leads to the BIP

1

 

 

2

 

 

 

 

 

 

 

 

+DC PS1 Upper

 

 

 

 

 

 

 

 

-DC PS1 Upper

3 2 1 3 2 1

 

3 2 1 3 2 1 A1 A2 B1 B2

PS (+)

PS (+) A/B Input Feed

PS (-)

PS (-)

– 48 VDC

Lower Shelf

Upper Shelf

Returns

Lower Shelf

Upper Shelf

A/B Input Feeds

3

 

 

 

 

 

1

= Positive lead wire from power

3 = Power terminal block label

 

supply 1, upper shelf

 

2

= Negative lead wire from power

 

 

supply 1, upper shelf

 

10393FA

Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis