Chapter 3 Problem solving 69

 

 

 

 

 

 

Table 4 BIP LEDs and indicators (continued)

 

 

 

 

 

 

 

Item

Label/Icon

Type

Color/State

Description

 

 

 

 

 

4

POWER

Indicator

White/On steady

Power indicator—The external DC power is

 

 

 

 

available to the BIP.

 

 

 

 

 

5

CRITICAL

Indicator

Red/On steady

Critical fault indicator—Indicates that a severe

 

 

 

 

service-affecting condition has occurred that

 

 

 

 

requires immediate corrective action. Common

 

 

 

 

causes for this type of fault condition include:

 

 

 

 

Line card failure

 

 

 

 

Temperature fault

 

 

 

 

• CPU fault when only one CPU is installed

 

 

 

 

 

6

MAJOR

Indicator

Red/On steady

Major fault indicator—Indicates that the system

 

 

 

 

hardware or software has identified a serious

 

 

 

 

disruption of service or that an important circuit

 

 

 

 

failure has occurred.

 

 

 

 

Common causes for this type of fault condition

 

 

 

 

include:

 

 

 

 

• CPU fault when two CPUs are installed

 

 

 

 

• Two fan trays are faulty

 

 

 

 

• A power supply circuit breaker has tripped due

 

 

 

 

 

to an overcurrent condition

 

 

 

 

• Two power supplies are faulty

 

 

 

 

 

7

MINOR

Indicator

Yellow/On steady

Minor fault indicator —Indicates a problem that

 

 

 

 

does not have a serious effect on customer service,

 

 

 

 

or a problem in circuits that are not essential to

 

 

 

 

device operation.

 

 

 

 

Common causes for this type of fault condition

 

 

 

 

include:

 

 

 

 

• Shelf alarm cables not installed or not

 

 

 

 

 

connected properly.

 

 

 

 

• Alarm module jumpers configured incorrectly.

 

 

 

 

• One power supply is faulty

 

 

 

 

• One fan tray is faulty

 

 

 

 

 

 

If you need more help, go to the next section, “Diagnosing and correcting the problem” on page 70.