July 2006 | Installing the 201i server in a large Meridian 1 system |
Before you begin
Before you can install the NTRH3501 cable, you must remove the existing backplane cable from the back of the switch. See “Removing the backplane (tip and ring) cables” on page 56.
To install the NTRH3501 backplane cable
1Install and connect the NTRH3501 cable to the multi I/O cable as follows:
a.Attach the backplane connector of the NTRH3501 cable to the inside of the I/O panel slot associated with the 201i server left slot.
Insert the original screw into the tie wrap base and fasten the screw into the lower position of the I/O panel slot.
b.Attach the three inner cables to the backplane connectors associated with the left slot as follows:
—UP 1 cable to the top position
—UP 2 cable to the middle position
—UP 3 cable to the lower position
ATTENTION |
| |
The connectors are keyed; you can insert them in | ||
| ||
| one position only. |
Use tie wraps to secure the cables in their original positions.
c.Connect the
201i Server Hardware Installation | 61 |