Installing the 201i server in an Option 11C or Option 11C Mini | Standard 1.03 |
Installing the 201i server in the Option 11C or Option 11C Mini switch
Introduction
The 201i server occupies physical and electrical slots. The 201i server must be installed in two peripheral equipment slots as follows:
Switch | Eligible slots |
|
|
Option 11C | Slots 1 through 9 in any cabinet |
|
|
Option 11C Mini | A pair of consecutive slots in any cabinet |
| Note: You cannot install the 201i server in slots 0 |
| or 4, because these slots are dedicated to other |
| cards. For more information about cards and slots, |
| refer to the Option 11C Mini documentation. |
|
|
To position the 201i server on the switch shelf
1Remove the front panel of the switch.
Note: On the Option 11C Mini, do the following:
a.Loosen the
b.Slide the cover to the left.
c.Pull the cover up to remove it from the cabinet.
70 | CallPilot |