The shaded rows indicate values that must be addressed by the

 

installer.

 

 

 

Table 6 Database Base tab

 

 

 

 

 

 

 

Parameter

Recommended value

Notes

Example

 

 

 

 

Primary Host

<machine logical IP of

 

120.120.13.22

 

database server>

 

 

 

 

 

 

 

 

Connections

8

 

 

default

 

 

 

 

 

Secondary Host

Not applicable

 

 

 

 

 

 

 

 

6Use the values from the table that follows to complete the SIP TCF Base tab parameters.

Table 7 SIP TCF Base tab

Parameter

Recommended value

Notes

Example

 

 

 

 

Transport Config

UDP=<machine logical

This is

UDP=120.120

 

IP of application server>

the IP

.13.25:5060:

 

:5060:optional:name=sip

address

optional:name

 

LscConduit;TCP=

of the

=sipLscCondu

 

<machine logical IP of

App svr

it;TCP=120.12

 

application server>:5060

 

0.13.25:5060:

 

:optional:name=sipLscC

 

optional:name

 

onduit

 

=sipLscCondu

 

 

 

it

 

 

 

 

Invite Timer

128000

 

default

 

 

 

 

Maximum Number of

5

 

default

Redirections

 

 

 

 

 

 

 

Initial Maximum Hop Value

20

 

default

 

 

 

 

7Use the values from the following table to complete the In Memory Database tab parameters.