Copyright © Nortel Networks Limited 2006

30

Connecting the Sun Fire V210 server to the MRV LX terminal server

The MCS 5100 platform uses the Sun Fire V210 server medium configuration.

Note: This server is only available in an AC power configuration.

Procedure 3 Connecting the serial port on the V210 to the MRV LX terminal server

At the back of the Sun Fire V210 server,

1Connect the Sun Fire V210 server Net MGT (LOM) serial port and Serial MGT port to the MRV LX terminal server:

Figure 7 Sun Fire V210 server network callouts

ATTENTION

If the network is down, or the server needs to be configured or restarted, use the console Net MGT port.

By default from manufacturing, the Net MGT serial port is the only active serial port.

Note 1: The cables with part numbers A0500465 or

NTVW01IM are serial cables.

Note 2: The P1 end goes to the V210 server and the P2 end goes to the MRV LX terminal server.

NN42020-310 MCS 5100 3.5 Standard 1.0 June 2006

Page 30
Image 30
Nortel Networks V210 (RoHS) manual Sun Fire V210 server network callouts