Copyright © Nortel Networks Limited 2006

131

3Use the values from the table that follows to complete the Web Client Manager tab parameters.

The shaded rows indicate values that must be addressed by the installer.

Table 26 Web Client Manager tab

 

Recommended

 

 

Parameter

value

Notes

Example

 

 

 

 

WCM Socket Server Active

checked

 

checked

 

 

 

 

WCM Socket Server Host

<machine logical IP

 

120.120.12.43

 

address of the Web

 

 

 

Client Manager>

 

 

 

 

 

 

WCM Socket Server Port

3090

 

default

 

 

 

 

Audio RTP Port Low

50000

 

default

 

 

 

 

Audio RTP Port High

50100

 

default

 

 

 

 

Use SSL

checked

 

default

 

 

 

 

Keep Alive Ping

checked

 

default

 

 

 

 

Ping Time Out Timer

60

 

default

 

 

 

 

Ping Interval Timer

120

 

default

 

 

 

 

Connection Time Out Timer

360

 

default

 

 

 

 

Allow Auto Login

checked

 

default

 

 

 

 

Download JRE Version

This field holds the version of the Java Runtime Environment

 

(JRE) installer that the Web Client applet downloads. For the

 

latest version of the installer from Sun, leave this field empty. For

 

the installer provided by the MCS (The MCS currently provides 5

 

different JRE installers.) , use string "1.4.2_01", "1.4.2_02",

 

"1.4.2_03", "1.4.2_04", or "1.4.2_05" for the corresponding

 

installer for JRE version 1.4.2_01, 1.4.2_02, 1.4.2_03, 1.4.2_04,

 

or 1.4.2_05. You may also provide a different JRE installer

 

(filename has to be j2re-windows-i586-p.exe) in the JRE installer

 

directory, which is the /IMS/web/data/web/webapps/pca/data/jar

 

directory on the server where the Provisioning Module runs. In

 

this case, use any other version string, such as "1.4.2_06". This

 

field should not contain white space.

 

 

 

 

 