Copyright © Nortel Networks Limited 2006
Verification procedures
Verifying Server1 (DBSvr/MgmtSvr/AcctMgr)
The following commands are executed on the database/management/accounting Sun Fire V210 server using PuTTY SSH into the machine logical IP address.
Example: Open a PuTTY SSH session to 120.120.13.22
Procedure 43 Verifying the database server
At the management pc,
1Log into the server as nortel/<new nortel user password>
2After the MCS Base Platform System Software installation, execute the following command to verify IP addressing.
@mcsmicromgmt]/export/home/nortel:=> ifconfig
lo0:
flags=1000849<UP,LOOPBACK,RUNNING,MULTICAST,IPv4 > mtu 8232 index 1 inet 127.0.0.1 netmask ff000000
bge0:
flags=9040843<UP,BROADCAST,RUNNING,MULTICAST,DE PRECATED,IPv4,NOFAILOVER> mtu 1500 index 2 inet 120.120.13.20 netmask ffffff00 broadcast 120.120.13.255
groupname imspub
bge0:1:
flags=1000843<UP,BROADCAST,RUNNING,MULTICAST,IPv 4> mtu 1500 index 2 inet 120.120.13.22 netmask ffffff00 broadcast 120.120.13.255
bge1:
flags=69040843<UP,BROADCAST,RUNNING,MULTICAST,D EPRECATED,IPv4,NOFAILOVER,STANDBY,INACTIVE> mtu 1500 index 3 inet 120.120.13.21 netmask ffffff00 broadcast 120.120.13.255 groupname imspub
3Look for the entry that starts with ‘bge0.’ The parameters that follow show the IP address, subnet mask, and whether the
MCS