Copyright © Nortel Networks Limited 2006

137

 

 

 

The shaded rows indicate values that must be addressed by the

 

installer.

 

 

 

Table 32 SIP TCF Base tab

 

 

 

 

 

 

 

 

 

Recommended

 

 

 

Parameter

Value

 

Notes

Example

 

 

 

 

 

Transport Config

UDP=<machine

 

Replace

UDP=120.120.13.25:

 

logical IP of the WCM

each

5080:optional;TCP=1

 

Server.>:5080:optiona

instance of

20.120.13.25:5080:o

 

l;TCP=<machine

 

0.0.0.0 in the

ptional;UDP=120.12

 

logical IP of the WCM

UDP and

0.13.25:5085:optiona

 

Server.>:5080:optiona

TCF strings

l:name=sipLscCondu

 

l;UDP=<machine

 

with the

it;TCP=120.120.13.2

 

logical IP of the WCM

machine

5:5085:optional:nam

 

Server.>:5085:optiona

logical IP

e=sipLscConduit

 

l:name=sipLscConduit

address of

 

 

;TCP=<machine

 

the Web

 

 

logical IP of the WCM

Client

 

 

Server.>:5085:optiona

Manager

 

 

l:name=sipLscConduit

Server

 

 

 

 

 

 

Invite Timer

128000

 

 

default

 

 

 

 

 

Maximum Number

5

 

 

default

of Redirections

 

 

 

 

 

 

 

 

 

Initial Maximum

20

 

 

default

Hop Value

 

 

 

 

 

 

 

 

 

3Use the values from the table that follows to complete the Web Client Manager tab parameters.

The shaded rows indicate values that must be addressed by the installer.

Table 33 Web Client Manager tab (Sheet 1 of 2)

 

Recommended

 

 

Parameter

value

Notes

Example

 

 

 

 

WCM Socket Server Active

checked

 

checked

 

 

 

 

WCM Socket Server Host

<machine logical IP

 

120.120.12.43

 

address of the Web

 

 

 

Client Manager>

 

 

 

 

 

 

WCM Socket Server Port

3090

 

default

 

 

 

 

MCS 2-server Sun Fire V210 (RoHS) Solaris Installation and Commissioning Guide

Page 137
Image 137
Nortel Networks V210 (RoHS) manual SIP TCF Base tab Recommended Parameter Value Example