Appendix D IBM ProPrinter Quick Refernce

Table 7: Further Control Sequences, supported by

IBM Emulation Mode (Native Commands)

Escape Sequence

Mnemonic Function

 

 

 

 

 

 

 

 

 

ESC [

 

$$

 

Control String Introducer (CSI) for 'ESC ['

ESC

 

$$/

 

Control String Introducer (CSI) for 'ESC'

 

ESC * P1 P2 P3 v1 . . . vn

 

 

Select Various Graphics Modes

 

 

 

 

 

P2 + P3 * 256 = number of columns

 

 

 

 

 

 

 

(P2,P3 = 0/0...F/F)

 

 

 

 

v1 .. vn = binary data in hex code

 

Parameter Table Graphic Density:

 

 

 

 

 

P1

Graphic type

 

dots

max.

hor.

vert.

vert.

 

 

 

 

per

of

density

density

density

 

 

 

 

column

columns

( dpi )

no AGM

AGM

 

0/0

Standard Density (K)

8

816

60

72

60

 

0/1

Double Density (L)

 

8

1632

120

72

60

 

0/2

2xDensity / 2xSpeed (Y)

8

1632

120

72

60

*)

0/3

Quadruple Density (Z)

8

3264

240

72

60

*)

0/4

CRT I

 

8

1088

80

72

60

 

0/5

Plotter

 

8

979

72

72

 

 

0/6

CRT II

 

8

1224

90

72

60

 

0/B

Double Density Plotter

8

1958

144

72

 

*)

2/0

Standard Density

 

24

816

60

180

180

 

2/1

Double Density

 

24

1632

120

180

180

 

2/6

CRT III

 

24

1224

90

180

180

 

2/7

Triple Density

 

24

2448

180

180

180

 

2/8

Hex Density

 

24

4896

360

180

180

*)

*) consecutive horizontal dots cannot be printed.

Example: box 8x8 dots with center point 2x2 dots, standard density, 8 dots / column

hex: 1B 2A 00 08 00 FF 81 81 99 99 81 81 FF