Maintenance ChapterInspectionsand 9
| Warning |
|
| WARNING | Alarm | Warning description |
| |
Priority | LCD indication | Tally lamp | and recording/playback | Countermeasures | ||||
| type |
|
| lamp | tone | operation |
| |
|
|
|
|
|
|
| ||
| Error of |
|
|
|
| An error in the camera section | Check the cause | |
| WARNING cause |
|
|
| is detected. Operation | indication*4 and | ||
7 | camera | Off | Off | No | ||||
indication*4 blinks red | continues, but abnormal | consult your | ||||||
| section |
|
|
| ||||
|
|
|
|
| shooting may occur. | distributor. | ||
|
|
|
|
|
| |||
|
|
| Blinks 4 |
| Continuous |
|
| |
| P2 card fully | P2 FULL | times per | Lights after | No more space on P2 | Delete clips that are | ||
8 | second after | completing | tone after | cards left for recording.Stop | no longer needed or | |||
recorded | Blinks red | completing | ||||||
| completion | recording | recording.*5 | insert a new card. | ||||
|
|
| of recording. |
| recording |
|
| |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| Check the number | |
|
|
|
|
|
| The synchronization of clip | and type of the | |
|
|
|
|
|
| clip. Or press the | ||
|
|
|
|
|
| position has failed. It may | ||
| Playback | SYNC POSI FAILED |
|
|
| STOP button to stop | ||
9 | Off | Off | No | occur when the reference | ||||
sync error | Blinks white | playback, check the | ||||||
|
|
|
| signal is unstable during 3D | ||||
|
|
|
|
|
| connection and/or | ||
|
|
|
|
|
| clip playback | ||
|
|
|
|
|
| the input signal, then | ||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| restart playback. | |
|
|
|
|
|
|
| Turn the power off | |
|
|
|
|
|
|
| and then back on | |
|
| REC WARNING | Blinks 4 | Blinks 4 | Intermittent | A recording error has | again and check | |
10 | Recording | Cause indication *6 | times per | times per | tone 4 | occurred. The error may | recording and | |
| error | Blinks red | second | second | times per | terminate recording. *7 | playback. Replace | |
|
| second | any P2 card that | |||||
|
|
|
|
|
| |||
|
|
|
|
|
|
| does not enable | |
|
|
|
|
|
|
| normal recording. | |
|
|
|
|
|
| (Continued on the next page) |
*4 Camera WARINNG cause indication
•FOCUS NG: Focus error (: L, R or L/R)
•ZOOM NG: Zoom error (: L, R or L/R)
•IRIS NG: Iris error (: L, R or L/R)
•ND FILTER NG: ND filter error (: L, R or L/R)
•CONV. NG: Convergence error (: L, R or L/R)
•SUB LENS NG:
*5 Perform either of the following procedures to cancel this warning.
•Press a playback control button.
•Press the THUMBNAIL button.
•Remove the P2 card and insert another card. *6 REC WARNING cause indication
•CARD ERROR: P2CARD error ( indicates the slot of the card with the error.) Stops recording.
•REC RAM OVERFLOW: Overflow of recording RAM. Stops recording.
•PULL DOWN ERROR: 24P, 30P (25P) video pulldown error. Recording continues.
•OVER MAX# CLIPS: Recording is interrupted as the limit for the number of clips that can be recorded to one P2 card has been reached.
•IRREGULAR FRM SIG: The reference signal, such as the GENLOCK input, is distorted.
•L/R DURATION NG: The duration of the recorded clip is different between the L and R P2 cards.
*7 Perform either of the following procedures to cancel this warning.
•Press the REC button.
•Press a playback control button.
•Press the THUMBNAIL button.
•Remove all cards.
128