DC OUT Connector and External REC Start/Stop Switch Connection

Preparation Chapter 5  

The DC OUT connector on the camera can output a 1.5 A current.

Connecting an external switch to this connector enables REC Start and Stop control.

An LED can be connected and used as a tally lamp, which is convenient when the camera is mounted on a crane during recording.

DC OUT connector

(Connection example)

 

 

Cable connector

4

1

HR10A-7P-4P(73)

3

2

Hirose Electric Co.

(For details on the

 

 

connector, refer to page 138.)

LED

Resist­ ance

REC

Start/Stop

Pin assignment

1GND

2TALLY OUT

The AG-3DP1 has open collector output.

TALLY ON:

Low impedance

TALLY OFF:

High impedance

3REC Start/Stop switch

This pin is connected in parallel with the REC button.

4+12 V

NOTE

Be sure to check polarity before connecting an external device as incorrect connection could lead to damage.

90