| Warning |
|
| WARNING | Alarm | Warning description |
| |
Priority | LCD indication | Tally lamp | and recording/playback | Countermeasures | ||||
| type |
|
| lamp | tone | operation |
| |
|
|
|
|
|
|
| ||
| Drop in |
| Blinks 4 |
|
| Indicates poor reception |
| |
| reception |
|
|
| Check microphone | |||
|
| times per | Blinks 4 |
| from the wireless receiver. | |||
| quality of | WIRELESS RF *8 |
| power supply and | ||||
11 | second | times per | No | Recording continues but | ||||
wireless | Blinks red | receiver reception | ||||||
| receiver |
| (Recording | second |
| wireless microphone cannot | status. | |
|
| only) |
|
| be received. | |||
| transmission |
|
|
|
| |||
|
|
|
|
|
|
| ||
|
| The last bar in the battery |
|
|
|
|
| |
|
| level indication blinks (This |
|
|
|
|
| |
12 | Battery | indication appears even if | Blinks 1 time | Blinks 1 time | No | The battery is near depletion. | Replace the battery | |
nearly empty | CARD/BATT is set to OFF | per second | per second | Operation continues.*9 | as necessary. | |||
|
| in the DISPLAY SETUP |
|
|
|
|
| |
|
| screen.) |
|
|
|
|
| |
|
|
| Blinks 1 time | Blinks 1 time |
| Less than 2 minutes is left on |
| |
| P2 card |
|
| the P2 cards (level indicator |
| |||
| The P2 card level indicator | per second | per second |
| Replace the P2 | |||
13 | nearly fully | No | shows 1 minute or less). This | |||||
blinks. | during | during | cards as necessary. | |||||
| recorded |
| recording. | recording. |
| warning appears only during |
| |
|
|
|
| recording. |
| |||
|
|
|
|
|
|
|
*8 The warning can be disabled by setting the WIRELESS WARN option on the AUDIO SETUP screen to OFF. *9 When NEAR END CANCEL is set to ON, you can press the DISP/MODE CHK button to cancel the alarm.
Maintenance ChapterInspectionsand 9
129