Panasonic AJ-D250P operating instructions Sets the signal to be regenerated when the TCG time code

Models: AJ-D250P

1 80
Download 80 pages 45.11 Kb
Page 48
Image 48

RS-232C

$Counter control commands

Sends data of computer

Return data from VTR

 

Description of command

 

 

 

 

 

 

 

 

 

[STX] CLP:data [ETX]

[STX] CLP [ETX]

Presets the designated counter value on the CTL counter.

Parameters

 

The value will be corrected as follows if the non-drop frame

data = ghmmssff

 

preset value has been set while the drop frame mode is

g = Blank: With a positive value

 

established.

 

– sign: With a negative value

 

00:01:00:00

00:00:59:28

h =

0

9: Hours

 

00:01:00:01

00:00:59:29

mm = 00

59: Minutes

 

<Note>

 

ss =

00

59: Seconds

 

This command is ignored while a search control command

ff =

00

29: Frames

 

is being processed or while the tape is being ejected.

 

 

 

 

 

[STX] CRN:m [ETX]

[STX] CRN [ETX]

Sets the signal to be regenerated when the TCG (time code

Parameters

 

generator) is set to the regeneration mode.

m = 0: TC & UB

 

<Note>

 

1: TC

 

 

This command is ignored while a search control command

2: UB

 

 

is being processed.

 

 

 

 

 

[STX] CRR [ETX]

[STX] CRR [ETX]

Uses the TCG in the REC RUN mode. The TCG counts up

 

 

 

 

during recording. The default value can be set using the

 

 

 

 

CTS command.

 

 

 

 

 

<Note>

 

 

 

 

 

This command is ignored while a search control command

 

 

 

 

is being processed, during recording and in the INSERT

 

 

 

 

mode.

 

 

 

 

 

 

[STX] CRT [ETX]

[STX] CRT [ETX]

Resets the CTL counter data.

 

 

 

 

<Note>

 

 

 

 

 

This command is ignored while a search control command

 

 

 

 

is being processed.

 

 

 

 

 

[STX] CTC [ETX]

[STX] CTC [ETX]

Uses the reference data for searching and for the display

 

 

 

 

mode of the counter display as the time code data.

 

 

 

 

<Note>

 

 

 

 

 

This command is ignored while a search control command

 

 

 

 

is being processed.

 

 

 

 

 

[STX] CTF [ETX]

[STX] CTF [ETX]

Uses the TCG in the FREE RUN mode.

 

 

 

 

The TCG continues to count up at all times regardless of

 

 

 

 

the mode. The default value can be set using the CTS

 

 

 

 

command.

 

 

 

 

 

The TCG starts counting up upon completion of the settings

 

 

 

 

and when the VTR’s power is turned back on.

 

 

 

 

<Note>

 

 

 

 

 

This command is ignored while a search control command

 

 

 

 

is being processed, during recording and in the INSERT

 

 

 

 

mode.

 

 

 

 

 

 

[STX] CTL [ETX]

[STX] CTL [ETX]

Uses the reference data for searching and for the display

 

 

 

 

mode of the counter display as the CTL data.

 

 

 

 

<Note>

 

 

 

 

 

This command is ignored while a search control command

 

 

 

 

is being processed.

 

 

 

 

 

[STX] CTM:m [ETX]

[STX] CTM [ETX]

Sets the mode used by the TCG.

Parameters

 

<Note>

 

m = 0: REC RUN mode

 

This command is ignored while a search control command

1: FREE RUN mode

 

is being processed, during recording and in the INSERT

2: Regeneration mode

 

mode.

 

3: External VITC mode

 

 

 

 

 

 

 

 

 

48

Page 48
Image 48
Panasonic AJ-D250P operating instructions Sets the signal to be regenerated when the TCG time code