Error Messages

When a problem has occurred in the unit, one of the following error messages will appear on the tape counter.

Error No.

 

Description

 

 

 

— d —

 

Condensation (dew) has formed.

 

 

 

 

 

Appears when the servo fails to lock for 3 or more

 

 

seconds.

E — 00

 

When T&S&R is selected as the setup menu item

 

No.001 setting, “SERVO NOT LOCKED” is

 

 

 

 

displayed on the third line (line where the remaining

 

 

tape amount is indicated) of the monitor screen.

 

 

 

 

 

Appears when there is no head output for one or

 

 

more seconds (due to clogging, etc.).

 

 

“L” is displayed on the first line (counter line) of the

E — 01

 

monitor screen.

 

When T&S&R is selected as the setup menu item

 

 

 

 

No.001 setting, “LOW RF” is displayed on the third

 

 

line (line where the remaining tape amount is

 

 

indicated) of the monitor screen.

 

 

 

 

 

Appears when a blank area on the tape has been

 

 

detected.

 

 

“N” is displayed on the first line (counter line) of the

 

 

monitor screen.

 

 

When T&S&R is selected as the setup menu item

 

 

No.001 setting, “NO RF” is displayed on the third

E — 09

 

line (line where the remaining tape amount is

 

 

indicated) of the monitor screen.

 

 

When all the following conditions are met, the part of

 

 

the tape is recognized as a blank.

 

 

ONo output from any of the heads

 

 

OPlayback data cannot be read

 

 

ONo CTL signal

 

 

 

E — 11

 

The reel base which operates in line with the size of

 

the tape has been locked for 2.5 or more seconds.

 

 

 

 

 

 

 

Four or more 4 seconds have elapsed after the

 

 

cassette was inserted but the cassette is not

E — 21

 

lowered down inside the unit.

 

Alternatively, 4 or more seconds have elapsed after

 

 

 

 

the eject operation was initiated but the cassette is

 

 

not ejected.

 

 

 

E — 31

 

The loading operation is not completed within 4

 

seconds.

 

 

 

 

 

E — 32

 

The unloading operation is not completed within 4

 

seconds.

 

 

 

 

 

E — 41

 

The FG signal (rotational speed signal) is not output

 

from the cylinder motor.

 

 

 

 

 

E — 42

 

The PG signal (phase signal) is not output from the

 

cylinder motor.

 

 

 

 

 

E — 43

 

The cylinder motor speed is abnormally high.

 

 

 

E — 44

 

The cylinder motor speed is abnormally low.

 

 

 

Error No.

Description

 

 

E — 51

The FG signal (rotational speed signal) is not output

from the capstan motor.

 

 

 

E — 52

The capstan motor speed is abnormally high.

 

 

E — 53

The capstan motor speed is abnormally low.

 

 

E — 61

The supply (S) reel motor is locked.

 

 

E — 62

The take-up (T) reel motor is locked.

 

 

E — 63

The supply reel motor speed is abnormally high.

 

 

E — 64

The take-up reel motor speed is abnormally low.

 

 

E — 65

Abnormal tension has been detected.

 

 

 

The start or end processing operation fails to be

E — 66

completed even after 7 or more seconds have

 

elapsed.

 

 

E — 67

A communication error between SERVO and

AVSYS. Errors in the data.

 

 

 

E — 68

A communication error between SERVO and

AVSYS. The data is fixed at high or low.

 

 

 

E — 69

A problem in communication between SERVO and

AVSYS when the power was switched on.

 

 

 

 

This appears when there is a communication error

E — 6B

between IF and AVSYS. There is a problem with the

 

internal reference or external reference.

 

 

 

The fan motor has stopped.

 

“S” is displayed on the first line (counter line) of the

 

monitor screen.

 

When T&S&R is selected as the setup menu item

E — 70

No.001 setting, “FAN STOP” is displayed on the

 

third line (line where the remaining tape amount is

 

indicated) of the monitor screen.

 

When about an hour elapses, the unit is shut down

 

automatically.

 

 

E — 72

There is a problem in the solenoid drive circuit.

 

 

E — 73

There is a problem in the cleaning solenoid drive

circuit.

 

 

 