Error Messages
When a problem has occurred in the unit, one of the following error messages will appear on the tape counter.
Error No. |
| Description |
|
|
|
— d — |
| Condensation (dew) has formed. |
|
|
|
|
| Appears when the servo fails to lock for 3 or more |
|
| seconds. |
E — 00 |
| When T&S&R is selected as the setup menu item |
| No.001 setting, “SERVO NOT LOCKED” is | |
|
| |
|
| displayed on the third line (line where the remaining |
|
| tape amount is indicated) of the monitor screen. |
|
|
|
|
| Appears when there is no head output for one or |
|
| more seconds (due to clogging, etc.). |
|
| “L” is displayed on the first line (counter line) of the |
E — 01 |
| monitor screen. |
| When T&S&R is selected as the setup menu item | |
|
| |
|
| No.001 setting, “LOW RF” is displayed on the third |
|
| line (line where the remaining tape amount is |
|
| indicated) of the monitor screen. |
|
|
|
|
| Appears when a blank area on the tape has been |
|
| detected. |
|
| “N” is displayed on the first line (counter line) of the |
|
| monitor screen. |
|
| When T&S&R is selected as the setup menu item |
|
| No.001 setting, “NO RF” is displayed on the third |
E — 09 |
| line (line where the remaining tape amount is |
|
| indicated) of the monitor screen. |
|
| When all the following conditions are met, the part of |
|
| the tape is recognized as a blank. |
|
| ONo output from any of the heads |
|
| OPlayback data cannot be read |
|
| ONo CTL signal |
|
|
|
E — 11 |
| The reel base which operates in line with the size of |
| the tape has been locked for 2.5 or more seconds. | |
|
| |
|
|
|
|
| Four or more 4 seconds have elapsed after the |
|
| cassette was inserted but the cassette is not |
E — 21 |
| lowered down inside the unit. |
| Alternatively, 4 or more seconds have elapsed after | |
|
| |
|
| the eject operation was initiated but the cassette is |
|
| not ejected. |
|
|
|
E — 31 |
| The loading operation is not completed within 4 |
| seconds. | |
|
| |
|
|
|
E — 32 |
| The unloading operation is not completed within 4 |
| seconds. | |
|
| |
|
|
|
E — 41 |
| The FG signal (rotational speed signal) is not output |
| from the cylinder motor. | |
|
| |
|
|
|
E — 42 |
| The PG signal (phase signal) is not output from the |
| cylinder motor. | |
|
| |
|
|
|
E — 43 |
| The cylinder motor speed is abnormally high. |
|
|
|
E — 44 |
| The cylinder motor speed is abnormally low. |
|
|
|
Error No. | Description | |
|
| |
E — 51 | The FG signal (rotational speed signal) is not output | |
from the capstan motor. | ||
| ||
|
| |
E — 52 | The capstan motor speed is abnormally high. | |
|
| |
E — 53 | The capstan motor speed is abnormally low. | |
|
| |
E — 61 | The supply (S) reel motor is locked. | |
|
| |
E — 62 | The | |
|
| |
E — 63 | The supply reel motor speed is abnormally high. | |
|
| |
E — 64 | The | |
|
| |
E — 65 | Abnormal tension has been detected. | |
|
| |
| The start or end processing operation fails to be | |
E — 66 | completed even after 7 or more seconds have | |
| elapsed. | |
|
| |
E — 67 | A communication error between SERVO and | |
AVSYS. Errors in the data. | ||
| ||
|
| |
E — 68 | A communication error between SERVO and | |
AVSYS. The data is fixed at high or low. | ||
| ||
|
| |
E — 69 | A problem in communication between SERVO and | |
AVSYS when the power was switched on. | ||
| ||
|
| |
| This appears when there is a communication error | |
E — 6B | between IF and AVSYS. There is a problem with the | |
| internal reference or external reference. | |
|
| |
| The fan motor has stopped. | |
| “S” is displayed on the first line (counter line) of the | |
| monitor screen. | |
| When T&S&R is selected as the setup menu item | |
E — 70 | No.001 setting, “FAN STOP” is displayed on the | |
| third line (line where the remaining tape amount is | |
| indicated) of the monitor screen. | |
| When about an hour elapses, the unit is shut down | |
| automatically. | |
|
| |
E — 72 | There is a problem in the solenoid drive circuit. | |
|
| |
E — 73 | There is a problem in the cleaning solenoid drive | |
circuit. | ||
| ||
|
|
74