RS-232C

$Query control commands

Sends data of computer

 

Return data from VTR

Description of command

 

 

 

 

 

 

 

 

[STX] QSP:m [ETX]

 

[STX] SMPdata [ETX]

Queries the repeat position which has been stored in the

Parameters

data = pw:ghmmssff

memory.

m =

OWhen CTL data is to be used as

Error code ER001 is returned from the VTR when the data

B: BEGIN point

the reference

 

has not been entered.

E: END point

pw =

BP: BEGIN point

 

 

 

EP: END point

 

 

g =

Blank:

With a positive value

 

 

 

– sign: With a negative value

 

 

h =

0

9:

Hours

 

 

mm =

00

59: Minutes

 

 

ss =

00

59: Seconds

 

 

ff =

00

29: Frames

 

 

OWhen TC data is to be used as the

 

 

reference

 

 

 

pw =

BP: BEGIN point

 

 

 

EP: END point

 

 

gh =

00

23: Hours

 

 

mm =

00

59: Minutes

 

 

ss =

00

59: Seconds

 

 

ff =

00

29: Frames

 

 

 

 

 

[STX] QTT [ETX]

 

[STX] TSTdata [ETX]

Queries the standby OFF timer which has been stored in

 

data = mmmm

 

the memory.

 

mmmm =

 

 

 

 

0000:

0.5 sec.

 

 

0005:

5 sec.

 

 

 

0010:

10 sec.

 

 

 

0030:

30 sec.

 

 

 

0100:

1 min.

 

 

 

0200:

2 min.

 

 

 

 

 

 

 

[STX] QVI [ETX]

 

 

[STX] VIm [ETX]

Queries the position of the INPUT SELECT switch.

 

m = L: LINE

 

 

 

S: S-VIDEO

 

 

 

D: OPTION

 

 

 

 

 

 

[STX] QVM [ETX]

 

[STX] VMDm [ETX]

Queries the color mode.

 

m = A: Color

 

 

 

B: Monochrome

 

 

 

 

 

 

 

63

Page 63
Image 63
Panasonic AJ-D250P operating instructions OWhen CTL data is to be used as, Reference, Video Option STX QVM ETX