RS-232C
$Search control commands
Sends data of computer | Return data from VTR |
| Description of command | |||
|
|
|
|
|
| |
|
|
|
|
|
| |
| [STX] SRS:data [ETX] | [STX] SRS [ETX] | Searches the counter value which was designated by the | |||
Parameters |
|
| parameter. | |||
data = wghmmssff |
| The STILL mode is established upon completion of the | ||||
OWhen CTL data is to be used |
| search. | ||||
as the reference |
| If the designated position is an illegal position (the target | ||||
w = L: CTL data reference |
| position does not exist), error code ER122 will be returned | ||||
g = Blank: With a positive value |
| from the VTR, which is then set to the STOP mode. | ||||
– sign: With a negative value |
| When the OSP (STOP) command or OEJ (tape EJECT) | ||||
h = | 0 | 9: Hours |
| command is issued during operation, error code ER123 is | ||
mm = 00 | 59: Minutes |
| returned from the VTR. | |||
ss = | 00 | 59: Seconds |
| If the VTR’s operation mode has been changed by | ||
ff = | 00 | 29: Frames |
| operating the controls on its front panel, error code ER121 | ||
OWhen TC data is to be used as |
| will be returned from the VTR. | ||||
the reference |
| If the tape end position is reached during operation, error | ||||
w = | S: TC data reference |
| code ER120 will be returned from the VTR. | |||
gh = | 00 | 23: Hours |
| When data differing from the data used as the reference | ||
mm = 00 | 59: Minutes |
| has been sent, error code ER001 will be returned from the | |||
ss = | 00 | 59: Seconds |
| VTR. | ||
ff = | 00 | 29: Frames |
| <Note> | ||
|
|
|
| This command is ignored while a search control command | ||
|
|
|
| is being processed and in any of the following modes. | ||
|
|
|
|
|
|
|
|
|
|
|
| EJECT, REC, REC PAUSE, INSERT, INSERT PAUSE |
|
|
|
|
|
|
| |
|
|
|
| |||
| [STX] SUB:data [ETX] | [STX] SUB [ETX] | Searches the start position of the user’s bit which was | |||
Parameters |
|
| designated by the parameter. | |||
data = uuuuuuuu:d |
| The STILL mode is established upon completion of the | ||||
u = 0 F: User’s bit value |
| search. | ||||
(“ ” is designated for a user’s bit |
| The search is enabled when the same user’s bit value | ||||
value which is not going to be |
| continues for at least 5 seconds. | ||||
searched) |
|
| When the OSP (STOP) command or OEJ (tape EJECT) | |||
d = F: Forward direction |
| command is issued during operation, error code ER123 is | ||||
| R: Reverse direction |
| returned from the VTR. | |||
|
|
|
| If the VTR’s operation mode has been changed by | ||
|
|
|
| operating the controls on its front panel, error code ER121 | ||
|
|
|
| will be returned from the VTR. | ||
|
|
|
| If the tape end position is reached during operation, error | ||
|
|
|
| code ER120 will be returned from the VTR. | ||
|
|
|
| <Note> | ||
|
|
|
| This command is ignored while a search control command | ||
|
|
|
| is being processed and in any of the following modes. | ||
|
|
|
|
|
| |
|
|
|
|
| EJECT, REC, REC PAUSE, INSERT, INSERT PAUSE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
69