Note

The air filter cleaning monitor (FILTER CLEANING) will flash blue while cleaning of the air filter is in progress. If there is a problem with the air filter, the air filter cleaning monitor (FILTER CLEANING) will light red.

The time taken for cleaning is approximately 30 to 40 seconds.

The setting time will be the local time. (p. 81)

Automatic cleaning will not be carried out if the projector is in standby mode.

If the projector is not in projection mode when the setting time is reached, automatic cleaning will not be carried out.

Automatic cleaning will not be carried out if 24 hours have not yet elapsed since cleaning was last carried out (either by automatic cleaning or forced cleaning).

Example: If the setting time is 7:00 and forced cleaning is carried out at 9:00, then automatic cleaning will not be carried out at 7:00 on the following day.

 

 

 

 

 

 

 

 

46 hours elapsed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22 hours elapsed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting time

Setting time

Setting time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Automatic

Forced

(No cleaning)

Automatic

cleaning

cleaning

 

 

 

 

 

cleaning

If the time is set to a time which is within 24 hours from the last time cleaning was carried out, automatic cleaning will not be carried out the next time the setting time is reached. Instead, cleaning will be carried out when the setting time is reached on the following day.

Example: If cleaning was carried out at 10:00, and the cleaning time setting is then changed to 20:00, automatic cleaning will be carried out at 20:00 on the following day.

34 hours elapsed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 hours elapsed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting time

Setting time

Setting time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Automatic

 

(No cleaning)

Automatic

 

cleaning

 

 

 

 

 

cleaning

Time reset

When projection starts (when the power is turned on), automatic cleaning will be carried out immediately if more than 24 hours have elapsed since cleaning was last carried out.

Setting the date and time

This lets you set the time zone and the current date and time for the projector’s internal clock.

1.Press ▲▼ to select “DATE AND TIME”.

OPTION2

PROJECTOR ID

2

 

INSTALLATION

FRONT-F

 

ALTITUDE

LOW

 

DIRECTION

H

 

LAMP SELECT

QUAD

 

LAMP RELAY

OFF

 

RS-232C

 

 

SYSTEM INFORMATION

 

 

AIR FILTER CLEANING

 

 

DATE AND TIME

 

 

STARTUP LOGO

LOGO1

 

PASSWORD

 

 

 

 

 

MENU SELECT

ENTER SUB MENU

2.Press ENTER.

The “DATE AND TIME” screen will be displayed.

DATE AND TIME

TIME ZONE

09:00

 

 

ADJUST CLOCK

 

 

 

LOCAL DATE

2007/01/01

 

 

 

 

 

 

LOCAL TIME

12:34:56

 

 

MENU SELECT

 

 

 

CHANGE

 

 

 

3.Press ▲▼ to select “TIME ZONE”.

4.Press ◄► to switch “TIME ZONE”.

5.Press ▲▼ to select “ADJUST CLOCK”.

6.Press ENTER.

The “ADJUST CLOCK” screen will be displayed.

ADJUST CLOCK

YEAR

2007

 

 

MONTH

1

 

 

DAY

1

 

 

 

 

 

 

HOUR

12

 

 

 

 

 

 

MINUTE

34

 

 

APPLY

 

 

 

MENU SELECT

CHANGE

7.Press ▲▼ to select the item to be set, and use ◄► to set the local time.

8.Use ▲▼ to select APPLY, and then press ENTER.

• This completes setting of the time.

Special Features

ENGLISH – 81

Page 81
Image 81