20 – ENGLISH

Adjusting the feet

The four adjustable feet mounted at the bottom of the projector are level-adjustable (0 mm–15 mm) which can be
used when the floor surface is not horizontal.

Projection scheme

This projector can use any of the four projection schemes. Select the most suitable scheme to the situation of your
location. Use the OPTION menu on the menu screen to choose the desired projection scheme. (p. 76)

Installation geometry

When planning the projector and screen geometry, refer to the figures below and the information on the next page
for reference. After the projector is roughly positioned, picture size and vertical picture positioning can be finely
adjusted with the powered zoom lens and lens shifting mechanism.
(Front) (Rear)(Front) (Rear)
Floor Ceiling
Front
Rear
Floor Ceiling
Front
Rear
254
580.5 - 700.5
H
H
SH
L
L
(10˝)
(22.9˝ - 27.6˝)
Lens Dimension of L1 (Approx.)
ET-D75LE1 62.5 (2.5˝)
ET-D75LE2 47 (1.9˝)
ET-D75LE3 50.5 (2˝)
ET-D75LE4 74.4 (2.9˝)
ET-D75LE5 150.5 (5.9˝)
ET-D75LE6 160 (6.3˝)
ET-D75LE8 202.5 (8˝)
* For PT-D10000U: H = 0 to SH
For PT-DW10000U: H = -0.1 × SH to 1.1 × SH
* However, if the ET-D75LE5 has been installed, the value
will be fixed at H=SH/2 for both the PT-D10000U and
PT-DW10000U. If the ET-D75LE6 has been installed,
the values will be H = 0.1 × SH to 0.9 × SH for the
PT-D10000U, and H = 0 to SH for the PT-DW10000U.
L
175
254
200
SW
314
120
66
(12.4˝)
(4.7˝)
(2.6˝)
(6.9˝)
(10˝)
(7.9˝)
L1
Top View (unit : mm/inch)
Screen
Side View (unit : mm/inch)
Screen
L: Projection distance SW: Image width
SH: Height of the image H:
Vertical distance between the
lens Center level and the bottom
edge of the projected image

When attaching an optional ceiling

mount bracket (ET-PKD100H)

254
580.5 - 700.5
H
H
SH
L
L
(10˝)
(22.9˝ - 27.6˝)
Lens Dimension of L1 (Approx.)
ET-D75LE1 62.5 (2.5˝)
ET-D75LE2 47 (1.9˝)
ET-D75LE3 50.5 (2˝)
ET-D75LE4 74.4 (2.9˝)
ET-D75LE5 150.5 (5.9˝)
ET-D75LE6 160 (6.3˝)
ET-D75LE8 202.5 (8˝)
* For PT-D10000U: H = 0 to SH
For PT-DW10000U: H = -0.1 × SH to 1.1 × SH
* However, if the ET-D75LE5 has been installed, the value
will be fixed at H=SH/2 for both the PT-D10000U and
PT-DW10000U. If the ET-D75LE6 has been installed,
the values will be H = 0.1 × SH to 0.9 × SH for the
PT-D10000U, and H = 0 to SH for the PT-DW10000U.
L
175
254
200
SW
314
120
66
(12.4˝)
(4.7˝)
(2.6˝)
(6.9˝)
(10˝)
(7.9˝)
L1
Top View (unit : mm/inch)
Screen
Side View (unit : mm/inch)
Screen
L: Projection distance SW: Image width
SH: Height of the image H:
Vertical distance between the
lens Center level and the bottom
edge of the projected image

When attaching an optional ceiling

mount bracket (ET-PKD100H)