Cleaning and replacement of air filter

If the air filter is blocked with too much dust, the inside of the projector will become hot and the temperature monitor (TEMP) indicator will flash and the power will turn off. The static electric mesh filter should be replaced and the metal mesh filter and brush inside the filter unit should be cleaned after approximately 2 000 hours of use, although this is a guide only and the actual time will vary depending on the operating conditions.

Procedure of cleaning

1.Turn off the main power and remove the power plug from the receptacle.

Turn off the main power supply observing the procedure (How to turn “OFF” the power supply) on page 36 and then remove the power plug.

2.Use a Phillips screwdriver to loosen the filter cleaning unit fixing screw at the front of the projector.

Insert your hand into the base of the air filter and pull the air filter forwards while removing the filter cleaning unit from the projector.

3.Remove the static electric mesh

filter from the filter cleaning unit.

• Loosen the static electric mesh filter so that it can be removed, and then remove it.

Filter cleaning unit

Static electric mesh filter

Filter cleaning unit fixing screw

4.

Place the filter cleaning unit

Brush cover fixing screws (4 places)

 

 

upside down.

 

5.

Remove the four brush cover

 

 

fixing screws, and then remove

 

 

the brush cover and the movable

 

 

metal mesh filter from the filter

 

 

cleaning unit.

Brush cover Movable metal mesh filter

 

 

6. Clean the filter cleaning unit, brush and movable metal mesh filter.

Use a vacuum cleaner to remove any dust blockages.

Movable metal mesh

Brush Filter cleaning

filter

unit

Brush cover

Brush

108 – ENGLISH

Page 108
Image 108
Panasonic DW10000U manual Cleaning and replacement of air filter, Procedure of cleaning, Place the filter cleaning unit