Option2 settings (continued)

Lamp select

This lets you switch the four light source lamps to one of four brightnesses in accordance with the operating conditions and purpose of use.

1.Press ▲▼ to select “LAMP SELECT”.

OPTION2

PROJECTOR ID

 

 

2

 

INSTALLATION

 

 

FRONT-F

 

ALTITUDE

 

 

LOW

 

DIRECTION

 

 

H

 

LAMP SELECT

 

 

QUAD

 

LAMP RELAY

 

 

OFF

 

RS-232C

 

 

 

 

SYSTEM INFORMATION

 

 

AIR FILTER CLEANING

 

 

DATE AND TIME

 

 

 

 

STARTUP LOGO

 

 

LOGO1

 

PASSWORD

 

 

 

 

MENU SELECT

 

 

 

 

CHANGE

ENTER

EXECUTE

2.Press ◄► to switch “LAMP SELECT”.

The setting will change as follows each time ◄► is pressed.

 

 

 

 

 

TRIPLE

 

QUAD

 

 

 

 

 

DUAL

 

L1

 

 

 

 

 

SINGLE

 

L2

 

 

 

 

 

L2/L3/L4

 

L3

 

 

 

 

 

L1/L3/L4

 

L4

 

 

 

 

 

L1/L2/L4

 

L1/L4

 

 

 

 

 

L1/L2/L3

 

L2/L3

 

 

 

 

 

QUAD” : The four lamps illuminate.

L1” : One lamp illuminates. (Lamp unit 1 takes priority.)

L2” : One lamp illuminates. (Lamp unit 2 takes priority.)

L3” : One lamp illuminates. (Lamp unit 3 takes priority.)

L4” : One lamp illuminates. (Lamp unit 4 takes priority.)

L1/L4” : Two lamps illuminate. (Lamp unit 1 and 4 take priority.)

L2/L3” : Two lamps illuminate. (Lamp unit 2 and 3 take priority.)

L1/L2/L3” : Three lamps illuminate. (Lamp units 1, 2 and 3 take priority.)

L1/L2/L4” : Three lamps illuminate. (Lamp units 1, 2 and 4 take priority.)

L1/L3/L4” : Three lamps illuminate. (Lamp units 1, 3 and 4 take priority.)

L2/L3/L4” : Three lamps illuminate. (Lamp units 2, 3 and 4 take priority.)

SINGLE” : One of the lamps illuminates. (The lamp unit with the shortest operating time is selected automatically.)

DUAL” : Two lamps illuminate.

(The lamp units with the shortest operating time out of lamp units 1 and 4 or 2 and 3 are selected automatically.)

TRIPLE” : Three lamps illuminate.

(The lamp unit with the shortest operating time is selected automatically.)

3.Press ENTER.

Note

For settings other than “QUAD”, any lamp which is malfunctioning or which has a cumulative operating time that exceeds 2 000 hours will be turned off and the other lamps will be turned on. If “QUAD” is selected, any lamp which is malfunctioning or which has a cumulative operating time that exceeds 2 000 hours will be turned off and only the lamps which have a cumulative operating time of less than 2 000 hours will be turned on. In addition, if the cumulative operating times for all lamps exceed 2 000 hours, the projector will switch to standby mode.

Lamp units which are not turned on should still be installed to the projector.

If the lamp selection is changed, picture is muted during lamp switching execution. (7-25 sec.)