IBM 9077 manual SP Switch Cable, Procedure for Connecting Cards to the SP Switch

Models: 9077

1 342
Download 342 pages 50.2 Kb
Page 98
Image 98

SP Control Workstation

Hub

SP Switch Router

Administrative Ethernet network

Control board

Figure 31. SP System Administrative Ethernet Connections

3.4.2 SP Switch Cable

The SP Switch Router Adapter card provides one full-duplex attachment and requires a specific cable with 50-pin connector ends, obtainable from IBM. The cable has a unique signal wiring map, and is not replaceable by a 50-pin HSSI cable, for example. SP Switch Router Adapter card cables are available in 10- and 20-meter lengths (32 or 65 feet). Excess cable lengths should be bound in a figure-eight pattern. Do not wind excess cable into circular coils.

Each connector end has 50 fragile pins. Pins can become bent when making the connection to the media card if alignment is wrong. If an SP Switch Router Adapter card link does not work after cabling, check both ends of the cable for bent pins. When not connected, keep the plastic caps on the ends.

3.4.3 Procedure for Connecting Cards to the SP Switch

This procedure connects the SP Switch Router Adapter card(s) to the SP Switch. Before the SP Switch Router unit can begin full operation, all other router media cards must be configured with appropriate customer configuration information.

Make sure you have labeled the SP Switch cable to show which media card and SP Switch port it will be connected to. Keep in mind that for any work done on the SP Switch you should have shut down and powered off the SP System and also turned off the central power supply switch at the left front edge of the SP.

Execute the following steps to make the connections:

1.If there are any terminators on the media card or the switch assembly where you need to attach the switch cable, remove them now.

Installation and Configuration

80

Page 98
Image 98
IBM 9077 manual SP Switch Cable, Procedure for Connecting Cards to the SP Switch