Indication of monitor lamp

Five monitor lamps are provided at the top of main unit front to inform the user of the lamp replacement time and unusual internal temperature. These lamps indicate the degree of abnormality by combination of blinking and/or lighting lamps. Turn off the power and take the proper measure according to the table below.

LAMP 4 monitor (LAMP 4)

LAMP 2 monitor (LAMP 2)

Temperature monitor (TEMP)

OPEN

FILTER

CLEANING

CLOSE

 

 

 

 

 

LAMP 1 monitor (LAMP 1)

 

 

 

 

LAMP 3 monitor (LAMP 3)

 

 

 

 

 

 

 

Name of

Lamp

 

 

 

 

 

monitor

Information

 

Check point

 

Remedial measure

indication

 

 

lamp

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Did you turn on the

Wait about five minutes in the current status.

 

 

Warm-up status

 

power when the

 

 

 

Install the unit in a location having an

 

 

 

ambient temperature

 

 

 

 

 

ambient temperature from 0 °C to 45 °C.

 

 

 

 

was low (approx. 0 °C)?

 

 

 

 

 

 

 

 

Lighting in

 

 

 

 

 

 

 

 

 

 

 

 

red

 

 

 

Remove the object that is blocking the

 

 

High temperature

Check if the ventilation

 

 

 

ventilation port.

TEMP

 

inside. (WARNING)

port is blocked.

Move the projector to a temperature of 0 °C

 

 

Is the room air

 

to 45 ˚C and the humidity of 20 % to 80 %

monitor

 

 

 

temperature too high?

(no condensation).

 

 

 

Is the air filter blocked

Turn off the MAIN POWER switch using the

 

 

 

 

Blinking in

High temperature

 

with dust?

 

procedure on page 36 and clean the air filter.

 

red

inside

 

 

 

(pp. 108-109)

 

(2 times)

(Standby condition)

 

 

 

 

 

 

 

 

 

 

 

 

Blinking in

Cooling fan has been

 

 

Turn off the main power supply (MAIN

 

red

stopped.

 

 

 

POWER) switch in the procedure shown on

 

(3 times)

 

 

 

page 36 and consult the distributor.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Did you notice a

This lamp monitor lights up when the lamp

 

Lighting in

Indicates the time for

 

“REPLACE THE LAMP”

 

 

message on the screen

 

unit used hours have reached 1 800 hours.

 

red

replacing the lamp unit.

 

 

 

 

when turning on the

 

Request the dealer to replace the lamp unit.

 

 

 

 

 

 

 

 

 

projector power supply?

 

 

 

 

 

 

 

 

 

LAMP

 

 

Did you turn the power

Wait until the lamp has cooled off, and then

 

 

 

back on immediately

monitor

 

 

 

 

turn on the power.

 

 

 

after turning it off?

 

 

 

 

 

 

 

 

Blinking in

Error is detected in the

 

 

 

 

 

Some error has arisen

 

 

 

red

lamp circuit.

Turn off the MAIN POWER switch using

 

(3 times)

 

 

in the lamp circuit.

 

 

 

Check for fluctuation

 

the procedure on page 36 and consult the

 

 

 

 

(or drop) in the source

 

dealer.

 

 

 

 

voltage.

 

 

 

 

 

 

 

 

 

Attention

Be sure to observe the procedure “Powering up the projector” (p. 35) and “Powering off the projector” (p. 36) when performing power supply operation to take a measure to the indication of temperature monitor (TEMP) lamp and lamp monitor (LAMP) lamp.

Information

ENGLISH – 107

Page 107
Image 107
Panasonic PT-D10000U, DW10000U manual Indication of monitor lamp, Lamp 1 monitor Lamp, Lamp 3 monitor Lamp