Troubleshooting

 

Table C-5

 

(1 of 2)

 

Modem ± VF Connection

 

 

Symptom

Action

 

 

Modem does not receive a

Check the VF line connection. Verify dial tone at the source.

dial tone

 

 

 

Modem does not go

Verify that the Auto-Answer Ring Count configuration option (S-register 0) is set to a value

off-hook and answer an

other than 0 (disable).

incoming call

Verify that the DTE is providing DTR to the modem.

 

 

 

 

If the DTE does not provide DTR to the modem, verify that the modem's &D command

 

(DTR Action configuration option) is set for Ignore (&D0).

 

 

 

Verify all cabling.

 

 

Modem goes off-hook,

Perform a Local Analog Loopback test and verify that data entered at the DTE is echoed

answers, but does not

back to the DTE.

connect

Verify that the originating modem is compatible.

 

 

 

 

Verify that originating modem recognizes your modem's answer tone.

 

 

Modem goes off-hook,

Verify that originating modem supports your modem's modulation schemes. The 3821Plus

answers, but does not

modem recognizes V.34, V.32terbo, V.32bis, V.32, V.22bis, V.22, V.21, Bell 212A, and

connect (continued)

Bell 103J. It does not support other vendors' proprietary modulation schemes.

 

 

 

Use the S41 register to force your modem to operate at the same modulation scheme as

 

the originating modem.

 

 

Originate Mode

Verify that the modem's DTE Dialer configuration option is set to the correct setting.

 

 

Modem does not go

If using AT Dialing, refer to the Table C-4, Modem ± DTE Connection.

off-hook and begin dialing

If using DTR Dialing, verify the telephone number stored in directory location 1, and verify

 

 

that the DTE is raising DTR from Off to ON to initiate a dial.

 

 

 

If using V.25bis Async, verify that the correct character format is set to 7 data bits with even

 

parity and 1 stop bit, and the carriage return and line feed are used as command

 

terminators.

 

 

 

If using V.25bis bisync, verify that the correct character format uses two synchronous

 

control characters and a start-of-text control character before the text block and an

 

end-of-text control character after the text block.

 

 

 

If using V.25bis HDLC, verify that the correct character format uses flag, address, and

 

control characters before the text block and a frame sequence check and flag after the text

 

block.

 

 

Modem dials but does not

If the modem is operating behind a PBX, determine if a 9 and comma are needed before

connect

the telephone number.

 

 

 

Determine whether Tone or Pulse dialing is needed.

 

 

 

Verify if one modem is configured for Error Control or Disconnect and the other modem is

 

configured for no Error Control. Try calling in Buffer mode.

 

 

 

If both modems use V.34, V.32bis, or V.32 modulation, set the modem's Train Time

 

configuration option to Long.

 

 

3821-A2-GB20-40

January 1999

C-3

Page 131