COMSPHERE 3821Plus Modem

Table 4-2

(7 of 10)

3821Plus S-Registers

S63 ± V.25bis Idle Character

Identifies to the modem the type of idle fill used by the DTE while in V.25bis HDLC or V.25bis Bisync mode.

Register has the following values:

0 = Mark

1 = Flag

Factory setting is Mark.

S64 ± V.25bis New Line Character

Identifies to the modem the type of line terminator used by the DTE while in V.25bis Async mode.

Register has the following values:

0 = Carriage Return and Line Feed

1 = Carriage Return

2 = Line Feed

Factory setting is carriage return and line feed (CR + LF).

S66 ± NMS Call Messages

Register determines if the modem sends information regarding status (Call Progress) and/or sends summarized call statistics (Call Connect) to the COMSPHERE 6700 Series NMS.

Register has the following values:

0 = Call Connect & Progress

1 = Disable

2 = Call Connect Only

3 = Call Progress Only

The value of S66 is not affected by factory default templates.

S69 ± Make Busy Via DTR

Determines if the modem goes off-hook (busy) when DTR is Off. In the UK, the default value cannot be modified.

WARNING: The Make Busy function must be used only when the modem is connected to a PBX, or to a local phone system that allows it.

Register has the following values:

0 = Disable

1 = Enable

Factory setting is Disable.

S74 ± Network Position Identification

Register identifies each modem as either a control or tributary modem.

Register has the following values:

0 = Tributary

1 = Control

Factory setting is Tributary.

S75 ± Network Management Address

Register determines the modem's network address. This address is used when accessing the modem from the NMS.

Enter a value from 0 (network address 001) to 255 (network address 256).

The value of S75 is 255 when the modem is shipped. The value of S75 is not affected by factory default templates.

4-22

January 1999

3821-A2-GB20-40

Page 98
Image 98
Paradyne 3821PLUS manual S63 ± V.25bis Idle Character, S64 ± V.25bis New Line Character, S66 ± NMS Call Messages