NOTE

If a connection is not established between a local COMSPHERE modem and a remote 3821Plus modem, the LCD displays Remote Mode Fail ± No Circuit. Press any key to return to the Top Level menu, and dial again.

If the remote modem accepts the password and the entry is successful, the Top-Level menu of the remote modem appears on the local modem's LCD. An appears in the upper right-hand corner indicating that what is displayed on your LCD is actually the Top-Level menu of the remote 3821Plus modem.

Online : 28.8

Control ExitRem

F1 F2 F3

The Top-Level menu of the remote 3821Plus modem is similar to the local COMSPHERE modem with the following exceptions:

The Modem Select branch (mdma, mdmb, mdmc) is displayed, but cannot be used to select modems. The modem under remote control is shown in uppercase characters.

Change Directory is the only function available under the Call Setup branch.

Self-Test and Local Analog Loop do not appear under the Test branch when using the secondary channel. When using the primary channel, the Test branch does not appear.

In the Control branch, Make Busy is not available.

The Security Branch is not available.

Exit Remote replaces Remote on the local modem's LCD.

(Modem Status) MDMA mdmb mdmc

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Call_Setup

 

Status

 

Test

 

Configure

 

Control

 

ExitRem

 

 

 

 

 

 

 

 

 

 

 

 

 

495-13082a-02

To return to local modem operation, select ExitRem. Any changes made to configuration options while using the Remote branch are not saved until you exit the Remote branch.

The following conditions can cause Remote Access to fail:

The local modem is not able to communicate with the remote modem because of a poor dial network or leased-line connection, or the remote modem is not a 3821Plus modem. If this is the case, the status message No Response appears on the LCD.

If a connection is established but the remote modem's Access from Remote configuration option is disabled, then the status message Access Disabled appears on the LCD.

If a connection is established but the wrong password is stored, the status message Password Invalid appears on the LCD.

6-2

January 1999

3821-A2-GB20-40